Regency P40-LP Indoor Fireplace User Manual


 
Regency
®
P40 Direct Vent Gas Fireplace 29
INSTALLATION
LOG SET INSTALLATION
INSTALLATION
Read the instructions below carefully and refer to the pictures. If the
logs are broken do not use the unit until they are replaced. Broken
logs can interfere with the pilot operation.
Log kit (Part # 502-930) contains the following pieces:
a) 03-32 Back Log
b) 03-40 Ember Bed
c) 03-34 Front Left Log
d) 03-33 Middle Back Log
e) 03-35 Middle Left Cross Log
f) 03-36 Middle Right Cross Log
g) 03-37 Front Right Log
h) 03-38 Right Side Ember Bed
i) 03-38 Left Side Ember Bed
j) 902-154 Embers Lava
k) 902-179 Vermiculite
1) Carefully remove the logs from the box and unwrap them. The logs
are fragile, handle with care - do not force into position.
2) Remove the brackets on the left and right side of the back air box.
03-38
Left
03-34
03-32
03-38
Right
03-33
03-35
03-36
03-37
03-40
3) Fit log 03-32 into the pins on the back air box. Push the log tight
against the back brick panel.
Back Air
Box
4) Re-install the brackets removed in step 2 to hold the log in place.
5) Place the Ember Bed on the 2 tabs located on the front burner. Then
slide the ember bed to the right until it touches the burner tube.
Front Burner
Ember Bed
Burner Tube
03-32