OPERATION
OPERATING INSTRUCTIONS
SUMMARY OF
CONTROLS
For the Manual Control Box, located on
right hand side of the bottom louver.
On/Off Button
If the unit is off, pressing and releasing this
button once will switch the unit on. The unit will
be on high for 20 seconds and then resume to
its last settings.
If the unit is on, pressing and releasing this
button once will switch the unit off.
Flame:
There are seven fl ame settings that can be
adjusted by pressing and releasing the plus (+)
and minus (-) FLAME button.
Increase: If the unit is on, pressing and releasing
the fl ame plus (+) button once will increase the
fl ame height to the next available high setting.
Decrease: If the unit is on, pressing and releasing
the fl ame minus (-) button once will decrease the
fl ame height to the next available low setting.
Fan:
There are three fan speeds that can be adjusted
by pressing and releasing the plus (+) and minus
(-) FAN button.
Pressing and releasing the plus (+) FAN button
will change the fan speed as follows:
OFF -> LOW -> MEDIUM -> HIGH -> OFF
Pressing and releasing the minus (-) FAN button
will be the reverse of the above.
OPERATION DURING
POWER OUTAGE
Important:
If the unit is not used for a prolonged period of
time, we recommend turning the 3-way switch
on the manual control panel to "Off". Also see
"Lighting Plate Instructions" for details on how to
turn off the pilot.
NOTE: The fan will not operate during a
power outage.
Rear Burner
Switch
3-way Switch
Manual Control Panel
When in "Remote" position;
In the event of a power failure, if the 3-way switch
is in the "Remote" position, the unit cannot be
operated with the Remote Control until after
power is restored.
To operate unit during a power failure;
NOTE: Both burners when on will operate at the
lowest fl ame setting. The BTU's for NG
will be 13,000 and 12,000 for LP.
Front Burner Operation:
1) Open the bottom louver to gain access to
the Manual Control Panel.
2) To turn on the front burner, change the 3-way
switch to "Manual" position.
Rear Burner Operation:
1) Open the bottom louver to gain access to
the Manual Control Panel.
2) To turn on the rear burner, change the Rear
Burner Switch to the "On" position. Changing
the switch to the "Off" postion will turn the
rear burner off.
Note: The rear burner will only operate if the
front burner is on.
Manual Control Box
Fan Control
Buttons
Unit
On/Off
Button
Flame
Control
Buttons
FIREWIZARD
TM
REMOTE
CONTROL FUNCTIONS
The FireWizard
TM
Remote Control was de-
veloped to provide a user-friendly system to
operate your appliance. The operating range
is approximately 10 metres (32 feet) from the
fi replace.
See FireWizard Remote Control Manual for
complete details on operation functions and
instructions.
When in "Manual" position;
In the event of a power failure, if the 3-way switch
is in the "Manual" position the front buner will
remain on at the lowest setting and will remain
on when power resumes. If the rear burner is
not in use, to operate see "Rear Burner Opera-
tion" above.
Both burners when on will operate at the lowest
fl ame setting. The BTU's for NG will be 13,000
and 12,000 for LP.
When power resumes the unit will remain on at
the lowest setting until reset using the remote
control.
NOTE: When power is restored, reset the
3-way switch on the Manual Control
Panel to the "Remote" position to be
able to use the FireWizard
TM
Remote
Control.