OPERATION
OPERATING INSTRUCTIONS
OPERATING
INSTRUCTIONS
1) Read and understand these instructions
before operating this appliance.
2) Check to see that all wiring is correct and
enclosed to prevent possible shock.
3) Check to ensure there are no gas leaks.
4) Make sure the glass in the door frame is
properly positioned. Never operate the
appliance with the glass removed.
5) Verify that the venting and cap are
unobstructed.
6) Ensure that the brick panels are installed.
7) Verify log placement. If the pilot cannot be
seen when lighting the unit, the logs have
been incorrectly positioned.
8) The unit should never be turned off, and on
again without a minimum of a 60 second
wait.
IMPORTANT Gas on/off knob cannot be
turned from "PILOT" to "OFF" unless it is
partially depressed.
Ensure that the 3 way switch on the manual
control panel is in the "Remote" position.
1) Push in gas control knob slightly and turn
clockwise to “OFF”. Knob cannot be turned
from “PILOT” to “OFF” unless knob is pushed
in slightly. Do not force.
2) Wait fi ve (5) minutes to clear out any gas.
3) Turn knob on gas control counterclockwise
to “PILOT”.
4) Push in control knob all the way and hold in
until the pilot lights up. Continue to hold the
control knob in for about 20 seconds after
the pilot is lit. Release knob and it will pop
back up. Pilot should remain lit. If it goes out,
repeat steps 1) to 4). If knob does not pop
up when released, stop and immediately
call your service technician or gas supplier.
If the pilot will not stay lit after several tries,
turn the gas control knob to “OFF” and call
your service technician or gas supplier.
5) Turn gas control knob counterclock-wise to
“ON”.
6) Turn the unit on.
NOTE: If using the remote control refer to
the FireWizard manual for instructions.
SHUTDOWN
PROCEDURE
1) Press the ON/OFF switch once.
2) The LED will ash.
3) Turn the main gas control clockwise to the
"OFF" position to turn off the pilot.
4) Turn off all electric power to appliance if
service is to be performed.
During the fi rst few res, a white fi lm
may develop on the glass front as part of
the curing process. The glass should be
cleaned after the unit has cooled down
or the fi lm will bake on and become very
diffi cult to remove. Use a non-abrasive
cleaner and DO NOT ATTEMPT TO CLEAN
THE GLASS WHILE IT IS HOT.
Only when the pilot holds, without pressure
being applied to the control knob, reapply the
tension springs to the door. The unit must
not be operated with the tension springs
unattached.
IMPORTANT
To ignite or reignite the pilot,
you must fi rst release the
tension springs below the door.
LIGHTING
PROCEDURE
The FIRST FIRE in your heater is part of the
paint curing process. To ensure that the paint
is properly cured, it is recommended that you
burn your fi replace for at least four (4) hours the
fi rst time you use it with the fan on.
When fi rst operated, the unit will release an
odour caused by the curing of the paint and the
burning off of any oils remaining from manufac-
turing. Smoke detectors in the house may go off
at this time. Open a few windows to ventilate
the room for a couple of hours. The glass may
require cleaning.
NOTE: The main burner will always start on
"HIGH" and resume it's last setting after
20 seconds of operation.
NOTE: When the glass is cold and the appliance
is lit, it may cause condensation and fog
the glass. This condensation is normal
and will disappear in a few minutes as
the glass heats up.
DO NOT ATTEMPT TO CLEAN THE
GLASS WHILE IT IS STILL HOT!
FIRST FIRE
DO NOT BURN THE APPLIANCE
WITHOUT THE GLASS FRONT IN
PLACE.
3-way Switch
Manual Control Panel