MAINTENANCE
MAINTENANCE
2) Disconnect the 2 DC Spark generator wires
from the DC spark box located on the right
side of the rebox.
DC SPARK BOX REPLACEMENT
5) Replace the DC spark box.
6) Reverse steps to re-install.
7) Spread the mesh along the rod ensuring that
it goes around the curved end of the rod.
3) Disconnect the spark electrode from the DC
spark box.
DC Spark Box
DC Spark Box
1) Gather the right side mesh together and slide
over to the center of the glass door to expose
the controls on the right side of the rebox.
DC SPARK
BOX BATTERY
REPLACEMENT
1) Gather the right side mesh together and slide
to the center of the glass door to expose the
controls on the right side of the rebox.
2) Remove the battery cover from the DC Spark
Box.
3) Remove AA battery and replace with a new
one.
4) Re-install battery cover on DC Spark Box.
5) Spread the mesh along the rod ensuring that
it goes around the curved end of the rod.
4) Remove the 2 screws that secure the DC
spark box in place.