Regency L676-1 Indoor Fireplace User Manual


 
Regency
®
L676-1 Direct Vent Gas Fireplace
30
INSTALLATION
BRICK PANEL INSTALLATION
IMPORTANT: Must install 1 set of brick panels. The operation of this unit without the brick panels is prohibited.
Dangerous operating conditions may occur if the panels are broken.
Handle with care. DO NOT FORCE INTO POSITION.
INSTALLATION
3) Remove the glass door.
a. Release the 2 door latches on the left and right side at the top of
the fi rebox.
Latch
b. Swing the door out from the top and release the hinge on the left
side of the door and lift out.
c. Place the door on a soft surface to prevent scratching.
4) Unwrap the brick panels from the protective wrapping.
Note: The logs must not be in the unit.
5) Remove the 2 brick panel clips on the inside top left and top right
side of the fi rebox by removing the screw.
Latch Location
Diagram 1
Diagram 2
Diagram 3
Diagram 4
Diagram 5
Diagram 6
Diagram 7
Screw
L676-1
L900-1
Brick
Panel
Clip
1) Remove the right side mesh by gathering the mesh together and
lifting the curved end of the rod up and out of the bracket located on
the top right of the glass frame.
Now slide the straight end of the rod out from the bracket located on
the middle inside top of the outer shell. Repeat for left side.
Door
Hinge
Front Cover Plate
Right Side Pin Shown
2) Remove the front cover plate by lifting up off of the pins on the left
and right side of the fi rebox.
Right Side Rod with
Screen Removed