INSTALLATION
OPTIONAL ANDIRON INSTALLATION
Optional Andiron installation for the L900-1:
1) Remove the mesh and the glass door (see Page 30 in the manual).
2) Remove Log G from the log set - see below.
Optional Andiron installation for the L676-1:
1) Remove the mesh and the glass door (see Page 30 in the manual).
2) Remove Log B from the log set - see below.
3) Slide bracket on the back of andiron over the 1st grate post.
4) Replace Log G.
3) Slide the bracket on the back of the andiron over the 1st grate
post.
4) Replace Log B (see below).
5) For the right side, slide the andiron bracket over the
4th grate post.
6) Reinstall glass door and mesh.
5) For the right side, slide the andiron bracket over the
4th grate post.
6) Reinstall glass door and mesh.
Log G
1st Grate Post
4th Grate Post
Log B
Final Installation L900-1 Final Installation L676-1
4th Grate Post
Right Side
1st Grate Post
Andiron Bracket
Andiron Bracket
Adjustments
Note: Andiron bracket
can be adjusted by
bending.
Also the screw can
be loosened so
the bracket can be
adjusted higher or
lower.
Log B