Regency L676-1 Indoor Fireplace User Manual


 
Regency
®
L676-1 Direct Vent Gas Fireplace
38
OPERATION
OPERATING
INSTRUCTIONS
1) Read and understand these instructions
before operating this appliance.
2) Check to see that all wiring is correct and
enclosed to prevent possible shock.
3) Check to ensure there are no gas leaks.
4) Make sure the glass in the door frame is
properly positioned. Never operate the
appliance with the glass removed.
5) Verify that the venting and cap are
unobstructed.
6) Ensure that the brick panels are installed.
7) Verify log placement. If the pilot cannot be
seen when lighting the unit, the logs have
been incorrectly positioned.
8) The unit should never be turned off, and on
again without a minimum of a 60 second
wait.
MATCHING REMOTE
CONTROL & RECEIVER
CODE
The Remote Control Handset has a set of unique
ID codes that is pre-programmed into its memory.
This set of ID codes helps to differentiate one
Remote Control Handset from another so that
only the control box with a matching ID code
will respond to the appropriate Remote Control
Handset.
To ensure the remote control is matched to
the receiver correctly, please follow the steps
below:
1) Install 4 "AA" batteries into the receiver.
2) Turn the 3-way switch on the receiver to the
"Remote" position.
3) Using a small pointy object (ie. the end of a
paper clip) press the button marked "PRG"
on the receiver. The receiver will beep 3 times
to indicate that it is ready to synchronize with
the remote control.
4) Install 3 "AAA' batteries into the remote con-
trol and push the "ON" button. The receiver
will beep 4 times to indicate the remote
control's command has been accepted and
sets to the particular code of that remote
control.
OPERATING INSTRUCTIONS
LIGHTING
PROCEDURE
NOTE: The Gas ON/OFF knob cannot be
turned from "ON", "PILOT" or "OFF" unless
it is partially depressed.
1) Ensure the 3-way switch on the wall mounted
receiver is in the "OFF" position.
2) Turn the gas control knob so the indicator
points to the "OFF" position and wait 5 min-
utes for any gas in the combustion chamber
to escape.
3) Turn the gas control knob counterclockwise
so the indicator points to the "PILOT" position.
Depress the gas control knob fully. Depress
the igniter button until the pilot lights. After
approximately one minute, release the gas
control knob. The pilot ame should continue
to burn.
Only when the pilot holds, without pressure
being applied to the gas control knob, re-install
the glass door to the unit. The unit must not
be operated without the glass door in place.
If the pilot does not remain lit, repeat opera-
tion allowing a longer period before releasing
gas control knob.
4) When the pilot stays lit, turn the gas control
knob to the "ON" position.
5) Use the wall switch or remote control to turn
the unit ON.
NOTE: When using the remote control refer to
the remote manual.
IMPORTANT
To ignite or reignite the pilot, you
must rst remove the glass door.
SHUTDOWN
PROCEDURE
1) Turn the 3-way switch on the wall mounted
receiver to the "OFF" position.
2) Press "OFF" on the remote control.
3) Turn the gas control knob to the "OFF" posi-
tion to turn off the pilot.
During the rst few res, a white lm
may develop on the glass front as part of
the curing process. The glass should be
cleaned after the unit has cooled down
or the lm will bake on and become very
dif cult to remove. Use a non-abrasive
cleaner and DO NOT ATTEMPT TO CLEAN
THE GLASS WHILE IT IS HOT.
The FIRST FIRE in your heater is part of the paint
curing process. To ensure the paint is properly
cured, it is recommended you burn your replace
for at least four (4) hours the rst time.
When rst operated, the unit will release an
odour caused by the curing of the paint and the
burning off of any oils remaining from manufac-
turing. Smoke detectors in the house may go off
at this time. Open a few windows to ventilate
the room for a couple of hours. The glass may
require cleaning.
NOTE: When the glass is cold and the appliance
is lit, it may cause condensation and fog
the glass. This condensation is normal
and will disappear in a few minutes as
the glass heats up.
DO NOT ATTEMPT TO CLEAN THE
GLASS WHILE IT IS STILL HOT!
DO NOT BURN THE UNIT WITHOUT
THE GLASS DOOR IN PLACE.
FIRST FIRE