National Instruments VME-PCI8022 Water System User Manual


 
Chapter 6 NI-VXI Configuration Utility
©
National Instruments Corporation 6-13 VXI/VME-PCI8022 for Solaris
Number of Interrupters
This field gives the number of interrupters that the PCI-MXI-2
supports.
Protocol Register
This field specifies the contents of the Protocol register, indicating
which protocols the device supports. This field is meaningful only when
the PCI-MXI-2 is configured as a message-based device. The default
value is 0x0ff0 (Commander, Signal Register, Master).
Read Protocol Response
This field specifies the response value to a Read Protocol command
received by the PCI-MXI-2 from the Resource Manager (if the
PCI-MXI-2 is not the Resource Manager in your system). This field is
meaningful only when the PCI-MXI-2 is configured as a message-based
device. The default value is 0x8448 (Response Generation, Event
Generation, Programmable Handler, Word Serial Trigger, Instrument,
Extended Longword Serial, Longword Serial).
Interrupters Default Value
0 to 7 0