4
GF 600 DV Firelight
Specifications
Input Rates
Natural Gas
40,000 BTU/hr. maximum input
28,600 BTU/hr. minimum input
Propane
40,000 BTU/hr. maximum input
30,900 BTU/hr. minimum input
Inlet Pressure: MIN MAX
Natural Gas: 5.0 WC (1.24 kPa) 7.0 WC (1.74 kPa)
Propane: 11.0 WC (2.74 kPa) 13.0 WC (3.23 kPa)
Manifold Pressure: MIN MAX
Natural Gas: 1.7 WC (.42 kPa) 3.5 WC (.87 kPa)
Propane: 6.4 WC (1.59 kPa) 10.0 WC (2.49 kPa)
Piezo Ignitor / Standing Pilot
Weight: 260 lbs.
29”
(74 cm)
Top Width
24”
(61 cm)
31”
(79 cm)
28 1/2”
(72.5 cm)
Leg Width
27 3/4”
(70.5 cm)
Exhaust
Outlet
Centerline
31 3/4”
(80.5 cm)
Co-Linear
Transition
Adaptor
Height
Co-linear Adapter (Simpson Dura-Vent #923GCL)
dimensions.
16”
(41 cm)
31 1/8”
(79 cm)
Top Exit
Flue
Collar
Height
Suggested Tools for
Installation and Service
• External regulator (for Propane only)
• Piping which complies with local code
• Manual shutoff valve - T-Handle in MA
• Sediment trap - if required by code
• Tee joint
• Pipe wrench
• Pipe sealant
• 10mm open end wrench
• 1/2”, 7/16” open end wrench or deep socket
• Phillips head screwdriver
• Flat head screwdriver
• 1/4” nut driver
• 4 mm allen wrench
• Gloves
• Safety glasses
• Torx T20 screwdriver
• Leak test solution
• Reciprocating Saw
• Power Drill
THIS FIREPLACE IS SHIPPED FROM THE
FACTORY FOR USE WITH
NN
NN
N
AA
AA
A
TURAL GASTURAL GAS
TURAL GASTURAL GAS
TURAL GAS
ONLY. IF USE WITH PROPANE IS DESIRED,
THE APPLIANCE MUST FIRST BE CON-
VERTED USING THE FUEL CONVERSION KIT
PROVIDED, #154391. CONVERSION SHOULD
BE MADE BEFORE THE APPLIANCE IS IN-
STALLED.