76 mm
12 
305
mm
2 1/2
64 mm
Figure 12. Horizontal Termination Clearance
* As specified in CGA B149 Installation Codes. Note: Local Codes and Regulations may require different clearances.
** A vent shall not terminate directly above a sidewalk or driveway which is located between two single family dwellings and serves both
dwellings.*
1
Only permitted if veranda, porch, deck, or balcony, is fully open on a minimum of two sides beneath the floor.*
Figure 13.
Termination clearance to
overhangs.
A = Clearance above grade, veranda, porch , deck, or
balcony : *12 inches (30 cm) minimum.
B = Clearance to window or door that may be opened: 9
inches (23 cm) minimum. We recommend 12 inches
(30 cm) minimum to help prevent condensation.
C = Recommended clearance to permanently closed
window: 9 inches (23 cm) minimum. We recommend
12 inches (30 cm) minimum to help prevent condensa-
tion on the window.
D = Vertical clearance to ventilated soffit located above
the terminal within a horizontal distance of 2 feet (60
cm) from the centerline of the terminal: 18 inches
(46 cm) minimum.
E = Clearance to unventilated soffit: 12 inches (46 cm)
minimum.
F = Clearance to outside corner: 9 inches (23 cm) min.
Jøtul N.A. strongly recommends 12 inches (30 cm),
particularly where windy conditions are prevalent.
G = Clearance to inside corner: 6 inches (16 cm) mini-
mum. Jøtul N.A. strongly recommends 12 inches (30
cm), particularly where windy conditions are prevalent.
H = *Not to be installed above a meter/regulator assem-
bly within 3 feet (90 cm) horizontally from the
centerline of the regulator.
I = Clearance to service regulator vent outlet: U.S. - 3 feet
CAN. 6 feet (1.8 m) minimum.
J = Clearance to nonmechanical air supply inlet to
building or the combustion air inlet to any other
appliance: *12 inches (30 cm) minimum.
K = Clearance to a mechanical air supply inlet: *6 feet
(1.8 m) minimum.
L = ** Clearance above paved sidewalk or a paved driveway
located on public property: *7 feet (2.1 m) min.
M = Clearance under veranda, porch, deck, or balcony: *12
inches (30 cm) minimum.