83
Replacing the light bulb
WARNING:
Turn the power off before replacing the light bulb.
The bulb could be HOT, wait until it has cooled down before
touching it.
To remove:
Remove the cap q.
Remove the setscrew w.
Remove the face cover e.
Pull out the bulb t from the lamp socket r.
To replace:
Insert a new bulb into the opening of the socket.
Attach the faceplate with the setscrew and cap.
q Cap
w Setscrew
e Face cover
r Lamp socket
t Light bulb
Replace the bulb with the same type, rated 12 V, 5 W.
q
w
e
r
t
Replacing the light bulb on the underside of
the sewing arm
Lay the machine on its back.
Remove the clear window q with the screwdriver as shown.
Pull out the lamp holder from the opening by hooking the
holder plate w with your fingertip.
Pull out the light bulb r from the socket e.
Insert a new bulb into the socket e.
Push the lampholder back into the opening.
Attach the window into the opening on the machine.
q Clear window
w Holder plate
e Lamp socket
r Light bulb
t Pins
Replace the bulb with the same type, rated 12 V, 5 W.
q
w
e
r
e
r
w
q