Icom IC-706MKIIG Home Security System User Manual


 
60
10
OPTIONAL INSTALLATIONS/SETTINGS
CR-282
HIGH
-
STABILITY CRYSTAL UNIT
By installing the CR-282, the total frequency stability
of the transceiver will be improved.
Remove the bottom cover as shown on the oppo-
site page.
Remove the 5 screws and 2 at cables holding the
PLL unit in place.
Remove the existing crystal unit.
Put the CR-282 in the space available as shown in
the diagram.
Adjust the reference frequency at L601 using a fre-
quency counter (60.00000 MHz).
Return the shield case and bottom cover to their
original positions.
CR-282 frequency stability: ±0.5 ppm
(30°C to +60°C;
22°F to +140°F)
IF filters
Several IF lters are available for the IC-706MKIIG.
Choose a lter most appropriate to your operating
needs.
Note: After lter installation, specify the installed lter
using initial set mode (items 9, 10). Otherwise, the
installed lter will not function properly.
FL-100
CW NARROW FILTER
500 Hz/6 dB
FL-101
CW NARROW FILTER
250 Hz/6 dB
FL-103
SSB WIDE FILTER
2.8 kHz/6 dB
FL-223
SSB NARROW FILTER
1.9 kHz/6 dB
FL-232
CW
/
RTTY NARROW FILTER
350 Hz/6 dB
Remove the top cover as shown on the previous
page.
Install the desired lter as shown in the diagram
below.
These lters can be installed in either direction.
Replace the top cover.
Filter
PLL unit
CR-282
Reference freq. check point
(60.00000 MHz)
ribbon
cable
ribbon
cable
existing
crystal
L601
PLL unit (bottom)