Icom IC-706MKIIG Home Security System User Manual


 
22
4
RECEIVE AND TRANSMIT
D RF gain and squelch
D Simple band scope
The IC-706MKIIG uses the same control, [RF/SQL],
to adjust one of either the RF gain or the squelch.
[RF/SQL] adjusts either the RF gain or the squelch
depending on the operating mode selected and the
condition of the RF gain item in initial set mode (p.
51; also see the table at right).
The
RF (Radio Frequency) gain is used to adjust the
receiver gain.
This control should be set to the 11 oclock position for
normal use.
Shallow rotation moves the S-meter to the right indicating
the signal strength which can be received.
The SQUELCH removes noise output from the
speaker (closed condition) when no signal is
received. The squelch is particularly effective for FM.
It is also available for the other modes.
When operating in FM, rst rotate the control fully coun-
terclockwise. Then, rotate the control clockwise to the
point where the noise just disappears. This is the best
position. The squelch does not open for weak signals
when it is set too deep.
A segment appears in the S-meter to indicate the S-meter
squelch level.
[RF/SQL] control priority
AF RF/SQL
Max. RF gain position
RF gain
decreases
Same effect as at
the center position
AF RF/SQL
Deep
Squelch
opens
S-meter squelch
threshold point
Noise squelch
threshold point
This function allows you to visually sweep an area
surrounding the set frequency for other signals.
Detected signals are indicated graphically in the dot
matrix section of the display.
Set a mode and frequency.
Select G1.
Push [DISPLAY] 1 or 2 times if M or S appears.
Push [MENU] one or more times to select
G1.
Push [F-1] one or more times to select the desired
steps.
Each dot corresponds to a step for the indicated fre-
quency.
0.5, 1, 2, 5, 10, 20 and 100 kHz can be set for the scope
step.
Push [F-3] to start the sweep.
•“___ (below SWP) ashes while sweeping.
The receive audio is muted while sweeping.
Rotate the main dial if you want to monitor the dis-
played signals.
The sweep marker indicates the location of the dis-
played frequency in the sweep readout.
If the displayed frequency is outside of the sweep read-
out (determined by the sweep width), the sweep mark-
er ashes.
Push [F-2] to return the frequency to the start of a
sweep.
The sweep marker moves back to the center position.
1k
SWP
2k
SWP
2k
SWP
2k
SWP
___
2k
SWP
Select sweep width
([F-1])
Start sweep
([F-3])
Sweep is finished
([F-3] again)
Move sweep marker
(main dial)
2k
SWP
Returns to previous
frequency ([F-2])
sweep marker
Note:The recommended
position for RF gain is the
11 oclock position since
this sets RF gain to the
max.
When set to AUTO, SQL is
active in FM/WFM/AM; RF
is active in SSB/CW/RTTY.
Note: Use the attenuator or turn OFF the preamp when
using the band scope on a band containing a lot of noise.
Initial set mode
setting
USB, LSB,
CW, RTTY
AM, FM, WFM
SQL*
1
SQL SQL
AUTO RF GAIN SQL
RF SQL*
2
RF/SQL RF/SQL
*
1
Default; *
2
Default for USA version.