Honeywell 68-0287-04 Thermostat User Manual


 
VISIONPRO
®
IAQ TOTAL HOME COMFORT SYSTEM
68-0287—04 20
Installer System Tests
When VisionPRO® IAQ is used in a zoning system you must exit the installer test on one thermostat before entering the installer
test on another thermostat.
OPERATION
Thermostat Keys
Thermostat Display
Table 4. Installer System Test.
System Test Number Test Type ISU Value System Status Number and Description
Test 1 Installer Test Cool 0
1
2
Off
Cool Stage 1
Cool Stages 1 & 2
Test 2 Installer Test Fan 0
1
Off
Fan On
Test 3 Installer Test Heat 0
1
2
3
4
Off
Heat Stage 1
Heat Stages 1, 2
Heat Stages 1,2,3
Heat Stages 1,2,3,4
Test 4 Emergency Heat Test 0
1
2
Off
AUX Heat Stage 1
AUX Heat Stages 1 and 2
Test 5 Installer Test Humidifier 0
1
Off
Humidifier On
Test 6 Installer Test Dehumidifier 0
1
Off
Dehumidifier On
Test 7 Installer Test Ventilator 0
1
Off
Ventilator On
Err Diagnostic Recall 00-99 See “Communication Error Codes” on page 35
Press the Next button to go to the beginning of the Installer Setup or press the Done button to exit the Installer System Test.
SCHED HOLD CLOCK SCREEN MORE
TUE
AM
FAN
AUTO
SYSTEM
HEAT
Following
Schedule
Inside
Set To
M23500
FAN
SELECTS
ON/AUTO/CIRC
SYSTEM
SELECTS EM.
HEAT/HEAT/OFF/COOL
UP ARROW
RAISES
TEMPERATURE
SETTING
DOWN ARROW
LOWERS TEMPERATURE
SETTING
SCHED
ENTERS
SCHEDULING
MODE
MORE
SHOWS ADDITIONAL
ACCESSORY AND
MAINTENANCE
OPTIONS
SCREEN
LOCKS OUT THE
SCREEN TO ALLOW
FOR CLEANING
CLOCK
SETS THE
TIME
FORWARD
OR BACK
HOLD
SETS A PERMANENT
HOLD AND ACTIVITIES
VACATION HOLD
Humidity
SCHED HOLD CLOCK SCREE MORE
TU
A
M
FAN
AUTO
SYSTEM
HEAT
Following
Schedule
Inside
Set To
M23501
FAN
SHOWS FAN
SETTING
TUE
SHOWS CURRENT DAY
OF THE WEEK
SYSTEM
SHOWS
CURRENT
SYSTEM
POSITION
TIME
DISPLAY CURRENT
TIME OF DAY, HOLD
TIME REMAINING OR
NUMBER OF VACATION
DAYS REMAINING
INSIDE TEMPERATURE
SHOWS THE CURRENT INSIDE
TEMPERATURE
SET TO
TEMPERATURE
SHOWS THE
CURRENT SET
TEMPERATURE
FOLLOWING
SCHEDULE
SHOWS THE
THERMOSTAT IS
FOLLOWING THE
PROGRAMMED
SCHEDULE
Humidity