Honeywell 68-0287-04 Thermostat User Manual


 
VISIONPRO
®
IAQ TOTAL HOME COMFORT SYSTEM
68-0287—04 18
510
USU
Humidifier Pad
Replacement
Reminder
E
0
1
2
3
Auto Discover
Disabled
90 C Days or 30 R.T. Days
180 C Days or 60 R.T. Days
365 C Days or 90 R.T. Days
Display will show Calendar Days if ISU372 = 0; Run
Time Days if ISU372 = 1 or 3.
520
USU
UV Lamp
Replacement
Reminder
E
0
1
2
Auto Discover
Disabled
365 Days
730 Days (2 years)
530
USU
Adaptive
Intelligent
Recovery
1
0
Adaptive
Conventional
See Temperature Recovery on page 32.
540
USU
Number of
Periods
4
2
4 Periods
2 Periods
4 periods = Wake, Leave, Return, and Sleep
2 periods = Wake and Sleep
550 Number of
Periods:
Weekdays
4
2
4 Periods
2 Periods
560 Number of
Periods:
Weekend Days
4
2
4 Periods
2 Periods
580 Min Compressor
Off Time
5
0
1
2
3
4
5 minutes
Off
1 minute
2 minutes
3 minutes
4 minutes
600 Heat Temp
Range Stops
90
40-90
Default = 90°F
40°F–90°F (Show 1/2 degree C)
610 Cool Temp
Range Stops
60
60-99
Default = 60°F
60°F–99°F (Show 1/2 degree C)
640
USU
Clock Format 12
24
12 Hour
24 Hour
650 Extended Fan on
time Heat (Blower
Off Delay Heat)
0
30
60
90
120
Off
30 seconds
60 seconds
90 seconds
120 seconds
660 Extended Fan on
time Cool (Blower
Off Delay Heat)
0
30
60
90
120
Off
30 seconds
60 seconds
90 Seconds
120 Seconds
This can be used to remove condensation from A-
coil; however, could re-introduce humidity into the
living space.
670
USU
Keypad Lockout 0
1
2
Unlocked
Partial Locked
Full Locked
680 Temp Control
Heat
2
1
3
Standard (recommended)
Less Aggressive temp control (may cause
temp undershoot)
More Aggressive temp control (may cause
temp overshoot)
690 Temp Control
Cool
2
1
3
Standard (recommended)
Less Aggressive temp control (may cause
temp undershoot)
More Aggressive temp control (may cause
temp overshoot)
700 Temperature
Display Offset
0
-3
-2
-1
1
2
3
0°F 0 °C — (no difference in
displayed temperature and actual room
temperature)
-3°F -1.5°C
-2°F -1°C
-1°F -.5°C
1°F .5°C
2°F 1°C
3°F 1.5°C
Table 3. Installer Setup Menu. (Continued)
ISU
Parameter
Number
Installer Setup
Name
Settings
(Factory Defaults Shown in Bold) Notes