36
3 in. (76 mm) tall legs
Ø 17 1/2 in. (444.5 mm) Round Hole to fit over cap
Length x Width to fit inside shroud
Figure 10.1 Radiation Shield
• Chase top shrouds may be field constructed where
permittedbyregionalbuildingcodes.
WARNING! Risk of Fire! Shrouds must be constructed as
specied. Improper construction may overheat chase top.
NOTICE: Some regional codes require an agency-Listed
shroud. Consult your local building ofcials.
10
Shrouds
• Hearth&Home TechnologiesInc.supplies UL listed
shrouds.Seeyourdealerfordetails.
• Different shroud designs have been tested for Hearth
TechnologiesreplacesystemsusingtheTR11andTR11T
terminationcaps.
• Theshroudsmustbeconstructedfromaminimum.018
in.(26ga)thickaluminizedsteel.
• Thewiremeshisoptionalbutrecommendedandmustbe
.018in.thickminimumwithmeshnolargerthan1/2in.
(13mm).
A. Radiation Shield
• Some shroudsrequirearadiationshield. Usewhere
specied.
Open Top Shroud (TR342 & TR11/TR11T caps require radiation shield)
3 in (76 mm)
minimum
Min.
Base Dim.
Min.
Base Dim.
Min.
Top Dim.
Min.
Top Dim.
Min. Opening
Width
Min. Opening
Width
Figure 10.2 Open Top Shroud Dimensions
TR11/11T TR11/11T TV
Min. Base Dims.
in 32x32 26x26
mm 813x813 660x660
RadiationShield
Required
Min. Top Dims.
in 29x29 23x23
mm 737x737 584x584
Min. Opening Width
in 26x26 20x20
mm 660x660 508x508
B. Field Constructed Shrouds