Heatiator BIR42 Indoor Fireplace User Manual


 
15
B. Design and Installation Considerations
Draftisthepressuredifferenceneededtoventreplaces
successfully.Whenareplaceisdraftingsuccessfully,all
combustionby-productsareexitingthehomethroughthe
chimney.
Considerationsforsuccessfuldraftinclude:
• Preventingnegativepressure
• Locationofreplaceandchimney
Beforeinstalling,determinethefollowing:
• Wherethereplaceistobeinstalled.
• Theventsystemcongurationtobeused.
• Gassupplypiping.
• Framingandnishingdetails.
• Whetheroptionalaccessoriesaredesired.
NOTICE: Check building codes prior to installation.
• InstallationMUSTcomplywithlocal,regional,stateand
national codes and regulations.
• Consult insurancecarrier, local building inspector, re
ofcialsorauthoritieshavingjurisdictionoverrestrictions,
installationinspectionandpermits.
Negativepressureresultsfromtheimbalanceofairavail-
ableforthereplacetooperateproperly.Itcanbestron-
gestinlowerlevelsofthehouse.
Causesinclude:
• Exhaustfans(kitchen,bath,etc.)
• Rangehoods
• Combustionairrequirementsforfurnaces,waterheaters
andothercombustionappliances
• Clothesdryers
• Locationofreturn-airventstofurnaceorairconditioning
• ImbalancesoftheHVACairhandlingsystem
• Upperlevelairleakssuchas:
- Recessedlighting
- Attichatch
- Ductleaks
Tominimizetheeffectsofnegativeairpressure:
• Ensureadequateoutdoorairforallcombustionappliances
andexhaustequipment
• Ensurefurnaceandairconditioningreturnventsarenot
locatedintheimmediatevicinityofthereplace
• Avoidinstallingthereplaceneardoors,walkwaysorsmall
isolated spaces
• Recessedlightingshouldbea“sealedcan”design
• Attichatchesweatherstrippedorsealed
• Atticmountedductworkandairhandlerjointsandseams
taped or sealed
• Basementinstallationsshouldbeavoided
WARNING! Risk of Asphyxiation! Negative pressure can
cause spillage of combustion fumes and soot. Fire must
draft properly for safe operation.
NOTICE: Hearth & Home Technologies assumes no
responsibility for the improper performance of the replace
system caused by:
Inadequate draft due to environmental conditions
Downdrafts
Tight sealing construction of the structure
Mechanical exhausting devices
Improper positioning of the chimney in a not-recommended
location on the roof.
NOTICE: Hearth & Home Technologies Inc. recommends the
use of direct vent appliances in basements.
D. Negative Pressure
C. Draft
NOTICE: The fireplace provides some outside air for
combustion. Other methods may be necessary if more air
is required.
Heatilator•BirminghamBIR42•4059-308RevJ•1/11