IntellireIgnitionSystem-(continued)
Symptom PossibleCause CorrectiveAction
4. Pilot lights but contin-
ues to spark, and main
burner will not ignite.
(If the pilot continues
to spark after the
pilot ame has been lit,
ame rectication has
not occurred.)
A. A shorted or loose connection in ame
sensing rod.
Verify all connections to wiring diagram in manual. Verify
connections underneath pilot assembly are tight. Verify con-
nections are not grounding out to metal chassis, pilot burn-
er, pilot enclosure or screen if present, or any other metal
object.
B. Poor ame rectication or contaminated
ame sensing rod.
With xed glass assembly in place, verify that ame is en-
gulng ame sensing rod on left side of pilot hood. Flame
sensing rod should glow shortly after ignition. Verify cor-
rect pilot orice is installed and gas inlet is set to pressure
specications. Polish ame sensing rod with ne steel wool
to remove any contaminants that may have accumulated on
ame sensing rod.
C. Module is not grounded. Verify module is securely grounded to metal chassis of ap-
pliance. Verify that wire harness is rmly connected to the
module.
D. Damaged pilot assembly or contami-
nated ame sensing rod.
Verify that ceramic insulator around the ame sensing rod
is not cracked, damaged, or loose. Verify connection from
ame sensing rod to white sensor wire. Polish ame sens-
ing rod with ne steel wool to remove any contaminants
that may have accumulated on ame sensing rod. Verify
continuity with a multimeter with ohms set at lowest range.
Replace pilot if any damage is detected.
E. Module. Turn ON/OFF rocker switch or wall switch to OFF position.
Remove ignitor wire “I” from module. Place ON/OFF rocker
switch or wall switch in ON position. If there is no spark at “I”
terminal module must be replaced. If there is a spark at “I”
terminal, module is ne.