Hearth and Home Technologies DV3732SBI Indoor Fireplace User Manual


 
Hearth & Home Technologies • DV3732SBI, DV3732SBIL • 2215-900 Rev. F • 9/1252
WHT
WHT
BLK
BLK
GRN wire
inside box
Copper
ground attached
to GRN screw with
GRN wire
14/2WG
Cover Plate
outside firebox
Romex
Connector
F. WallSwitchInstallationforFan(Optional)
If the box is being wired to a wall mounted switch for use
with a fan (See Figure 12.4):
• The power supply for the appliance must be brought into
a switch box.
• The power can then be supplied from the switch box to the
appliance using a minimum of 14-3 with ground wire.
• At the switch box connect the black (hot) wire and red
(switch leg) wire to the wall switch as shown.
• At the appliance connect the black (hot), white (neutral)
and green (ground) wires to the junction box as shown.
• Add a 1/4 in. insulated female connector to the red (switch
leg) wire, route it through the knockout in the face of the
junction box, and connect to the top fan switch connector
(1/4 in. male) as shown.
Figure12.3JunctionBoxDetail
NOTICE: DO NOT wire
110 VAC to wall switch.
Red
Switch
Switch Box
Red
Black
Black
Green
Green
White
Power
Supply
Wires
White
Red
Black
Green
White
Minimum 14-3 AWG
with Ground
Junction Box
Knockout
Figure12.4JunctionBoxWiredtoWallSwitchorBC10
E. JunctionBoxInstallation
If the box is being wired from the INSIDE of the appli-
ance:
• Remove the screw attaching the junction box/receptacle
to the outer shell, rotate the junction box inward to dis-
engage it from the outer shell (see Figure 12.3).
• Pull the electrical wires from outside the appliance through
the opening into the valve compartment and secure wires
with a Romex connector. See Figure 12.3.
• Make all necessary wire connections to the junction
box/receptacle and reattach the junction box/receptacle
to the outer shell.