Hearth and Home Technologies DV3732SBI Indoor Fireplace User Manual


 
Hearth & Home Technologies • DV3732SBI, DV3732SBIL • 2215-900 Rev. F • 9/1256
C. FacingMaterial
• Metal front faces may be covered with non-combustible
materials only.
• Facing and/or nishing materials must not interfere with
air ow through louvers, operation of louvers or doors,
or access for service.
• Facing and/or nishing materials must never overhang
into the glass opening.
• Observe all clearances when applying combustible
materials.
• Seal joints between the nished wall and appliance top
and sides using a 300ºF minimum sealant. Refer to
Figure 13.16.
WARNING! Risk of Fire! DO NOT apply combustible
materials beyond the minimum clearances. Comply with
all minimum clearances to combustibles as specied in
this manual. Overlapping materials could ignite and will
interfere with proper operation of doors and louvers.
0 IN.
0 IN.
0 IN.
FINISH WALL MATERIAL MAY BE
COMBUSTIBLE - TOP AND SIDES
HIGH TEMPERATURE SEALANT (300° F/149° C MIN.)
TOP AND SIDE SEAL JOINT
Figure13.16NoncombustibleFacingDiagram