Initial Break-in Procedure
• The fireplace should be run three to four hours
continuously on high.
• Turn the replace off and allow it to completely cool.
• Remove xed glass assembly. See Section 14.G.
• Clean xed glass assembly. See Section 3.
• Replace the xed glass assembly and run continuously
on high an additional 12 hours.
This cures the materials used to manufacture the re-
place.
NOTICE! Open windows for air circulation during re-
place break-in.
• Some people may be sensitive to smoke and odors.
• Smoke detectors may activate.
J. AfterFireplaceisLit
K. FrequentlyAskedQuestions
ISSUE SOLUTIONS
Condensation on the glass
This is a result of gas combustion and temperature variations. As the replace warms, this
condensation will disappear.
Blue ames
This is a result of normal operation and the ames will begin to yellow as the replace is al-
lowed to burn for 20 to 40 minutes.
Odor from replace
When rst operated, this replace may release an odor for the rst several hours. This is caused
by the curing of the paint and the burning off of any oils remaining from manufacturing. Odor may
also be released from nishing materials and adhesives used around the replace.
Film on the glass
This is a normal result of the curing process of the paint and logs. Glass should be cleaned
within 3 to 4 hours of initial burning to remove deposits left by oils from the manufacturing
process. A non-abrasive cleaner such as gas replace glass cleaner may be necessary. See
your dealer.
Metallic noise
Noise is caused by metal expanding and contracting as it heats up and cools down, similar to
the sound produced by a furnace or heating duct. This noise does not affect the operation or
longevity of the replace.
Is it normal to see the pilot ame burn
continually?
In an Intellire ignition system it is normal to see the pilot ame, but it should turn off when ON/
OFF is turned off.