Hearth and Home Technologies DV3732SBI Indoor Fireplace User Manual


 
31
Hearth & Home Technologies • DV3732SBI, DV3732SBIL • 2215-900 Rev. F • 9/12
INSTALLED
HORIZONTALLY
H
3
H
1
H
2
V
1
H
1
MAX. V
1
MIN. H
2
MAX. H
1
+H
2
MAX.
1-1/2 ft. 457 mm Back to back elbows 1 ft. 305 mm 2-1/2 ft. 762 mm
3 ft. 914 mm 1 ft. 305 mm 3 ft. 914 mm 6 ft. 1.8 m
5 ft. 1.5 m 3 ft. 914 mm 5 ft. 1.5 m 10 ft. 3.0 m
7 ft. 2.1 m 5 ft. 1.5 m 7 ft. 2.1 m 14 ft. 4.3 m
H
1
MAX. = 7 ft. (2.1 m)
H
1
+ H
2
MAX. = 14 ft. (4.3 m)
V
1
+ H
1
+ H
2
MAX. = 40 ft. (12.2 m)
Figure7.14
H
1
MAX. V
1
MIN. H
2
+H
3
MAX. H
1
+H
2
+H
3
MAX.
1-1/2 ft. 457 mm Back to back elbows 1 ft. 305 mm 2-1/2 ft. 762 mm
3-1/2 ft. 1.1 m 1 ft. 305 mm 2 ft. 610 mm 5-1/2 ft. 1.7 m
5-1/2 ft. 1.7 m 2 ft. 610 mm 4 ft. 1.2 m 9-1/2 ft. 2.9 m
7-1/2 ft. 2.3 m 3 ft. 914 mm 6 ft. 1.8 m 13-1/2 ft. 4.1 m
H
1
MAX. = 7-1/2 ft. (2.3 m)
H
1
+ H
2
+ H
3
MAX. = 13-1/2 ft. (4.1 m)
V
1
+ H
1
+ H
2
+ H
3
MAX. = 40 ft. (12.2 m)
Figure7.15
Note: Use DVP Series
components only.
Note: Use DVP Series
components only.
H
1
H
2
V
1
TwoElbows
3. RearVent-HorizontalTermination-(continued)
ThreeElbows