Hearth and Home Technologies DV3732SBI Indoor Fireplace User Manual


 
Hearth & Home Technologies • DV3732SBI, DV3732SBIL • 2215-900 Rev. F • 9/1226
H
2
H
1
V
2
V
1
ThreeElbows
V
1
Minimum** H
1
Maximum H
1
+H
2
Maximum
90 Elbow Only** 1-1/2 ft. 457 mm 2 ft. 610 mm
1/2 ft.** 152 mm 1-1/2 ft. 457 mm 4 ft. 1.2 m
1-1/2 ft. 457 mm 3 ft. 914 mm 6 ft. 1.8 m
2-1/2 ft. 762 mm 5 ft. 1.5 m 10 ft. 3.0 m
3-1/2 ft. 1.1 m 7 ft. 2.1 m 14 ft. 4.3 m
4-1/2 ft. 1.4 m 14 ft. 4.3 m 14 ft. 4.3 m
H
1
+ H
2
MAX. =14 ft. (4.3 m)
V
1
+ V
2
+ H
1
+ H
2
MAX. = 40 ft. (12.2 m)
** See Warning Below.
Note: There MUST be a 25% reduction
in total H when using ex vent except
when using the simple up and out
installation (see Figure 7.3).
Fire Risk.
When using SLP-HRC-SS and SLP-HRC-ZC-
SS termination caps on top vented replaces,
a one foot minimum vertical vent section is
required before installing rst elbow.
WARNING**
1. TopVent-HorizontalTermination - (continued)
Figure7.6
Note: Use SLP Series
components only.