Change during operation: N = impossible, Y* = possible (enabled by using ),
Y
= possible (enabled by using
)
-
35
-
FUNC
DATA
Func-
tion
code
No.
Name Setting range Unit
Min.
unit
Factory
setting
Change
during
operation
User
setting
E01
X1 terminal function
-
-
0
N
E02
X2 terminal function
-
-
2
N
E03
X3 terminal function
Use the code values listed below to se-
lect [X1], [X2] and [X3] terminal func-
tions.
-
-
3
N
0: Multistep frequency 1 (SS1)
1: Multistep frequency 2 (SS2)
2: Coast-to-stop command (BX)
3: Alarm reset (RST)
4: External alarm (THR)
5: Write enable command for keypad
(WE-KP)
6: PID control cancel (Hz/PID)
7: Link operation selection (LE)
Func-
tion
code
No.
Name Setting range
Unit
Min.
unit
Factory
setting
Change
during
operation
User
setting
C01
Jump frequency 1
0 to 120Hz Hz 1 0 Y
C02 2 1 0 Y
C03 3 1 0 Y
C04
(Hysteresis)
0 to 30Hz Hz 1 3 Y
C05 Multistep frequency 1 0.0 to 120Hz Hz 0.1 0.0 Y
C06 2 0.1 0.0 Y
C07 3 0.1 0.0 Y
E: Extension Terminal Functions
C: Control Functions of Frequency