FMI (V)T32N-A Indoor Fireplace User Manual


 
www.fmiproducts.com
116646-01J6
PRE-INSTALLATION PREPARATION
Continued
NOTICE: This replace is in-
tended for use as supplemental
heat. Use this replace along
with your primary heating sys-
tem. Do not install this replace
as your primary heat source.
If you have a central heating
system, you may run system’s
circulating blower while using
replace. This will help circulate
the heat throughout the house.
In the event of a power outage,
you can use this replace as a
heat source.
FRAMING AND FINISHING
Figure 4 shows typical framing of this replace.
Figure 5 shows framing for corner installation.
All minimum clearances must be met.
For available accessories for this replace,
see Accessories on page 37. If you are using
a separate combustible mantel piece, refer to
Figure 6 for proper installation height. You can
install noncombustible mantels at any height
above the replace. Note: Noncombustible
mantels may discolor!
32
3
/8"
34
5
/8"
17" Horiz. Vent
20" Vert. Vent
Figure 5 - Framing Clearances for Corner
Installation
A
B
E
F
G
H
D
C
Nailing Tabs
28
1
/
2
"
13
5
/
8
"
39
3
/
8
"
9
1
/
2
"
9
7
/
8
"
34
3
/
8
"
54
1
/
8
"
Nailing
Tabs
C
B
A
D
E
F
G
To p of Louver
Opening
3
2
1
4
5
6
7
Wall
Figure 6 - Clearances for Combustible
Mantels
34
5
/
8
"
Figure 4 - Framing Clearances for
Installation Against an Exterior Wall
Ref.
Mantel
Depth Ref.
Mantel from
Top of Louver
Opening
1 14" A 16"
2 12" B 14"
3 10" C 12"
4 8" D 10"
5 6" E 8"
6 4" F 6"
7 2" G 4"