FMI (V)T32N-A Indoor Fireplace User Manual


 
www.fmiproducts.com
116646-01J 29
Auto Shutoff Feature
1. If the average room temperature reaches
a range of 82° F (28° C) to 92° F (33° C),
the hand-held remote control will perform
a safety override and shut the replace off.
This feature is not available in the MANU
mode.
2. The receiver continuously receives sig-
nals from the hand-held remote to control
the room temperature. If the hand-held
remote is misplaced, obstructed or for any
reason cannot transmit to the receiver, the
receiver will shut off the replace. This will
occur in 8 or more minutes depending
upon location of remote transmitter and
strength of batteries.
Key Pad Lock Feature
This feature allows the user to lock/unlock the
keypad on the hand-held remote in the MANU
or AUTO mode to prevent inadvertent op-
eration (i.e. children operating the hand-held
remote control, etc.). The keypad is locked in
either on or off. Press the POWER and LOCK
buttons together to turn the unit on or off.
OPERATING OPTIONAL
GWMT1 WALL MOUNTED
THERMOSTAT
WARNING: Do not con-
nect the thermostat to a power
source. Electrical shock and/or
a re hazard will occur.
Light the replace as instructed in Lighting
Instructions on page 27. Set wall thermostat
to desired temperature.
OPERATION
Continued
This thermostat has been electronically cali-
brated at the factory and requires no adjust-
ment or leveling.
Upon installation, thermostat must be allowed
to stabilize at room temperature for a mini-
mum of 30 minutes for proper operation.
To turn replace off, adjust thermostat to the
lowest setting and turn gas control knob back
to PILOT. The pilot will remain lit.
IMPORTANT: To turn pilot off, turn gas control
knob on heater to the OFF position.
OPERATING OPTIONAL
BLOWER ACCESSORY
Locate blower controls by opening lower
louver panel on replace. Blower controls are
located on the right side of switch bracket to
the left just inside louver panel.
The BK manual blower and BKT thermostati-
cally-controlled blower have an ON setting
and an OFF setting. Blower will only run when
the switch is in the ON position. In the OFF
position, blower will not operate.
Note for BKT Only: If you are using BKT
blower with optional thermostat (wall mounted
or remote control) for the replace, your re-
place and blower will not turn on and off at
the same time. Fireplace may run for several
minutes before blower turns on. After heater
modulates to the pilot position, blower will
continue to run. Blower will shut off after
rebox temperature decreases.
The blower helps distribute heated air from the
replace. Periodically check louvers of rebox
and remove any dust, dirt or other obstruc-
tions that will hinder the ow of air.
Thermocouple
Thermopile
1/8"
Pilot
Burner
Piezo
Ignitor
Figure 55 - Pilot Assembly
3/8" to 1/2"
INSPECTING BURNERS
Check pilot ame pattern and burner ame
patterns often.
PILOT ASSEMBLY
The pilot assembly is factory preset for the
proper ame height. Alterations may have
occurred during shipping and handling. Call
a qualied service person to readjust the pilot
if necessary.
The height of the thermopile must be 3/8"
to 1/2" above pilot ame as shown in Figure
55. The thermocouple must be at a height of
about 1/8" above pilot ame. The ame from
pilot burner must extend beyond both the
thermocouple and thermopile.