FMI (V)T32N-A Indoor Fireplace User Manual


 
www.fmiproducts.com
116646-01J36
SPECIFICATIONS
REPLACEMENT PARTS
Note: Use only original replacement parts.
This will protect your warranty coverage for
parts replaced under warranty.
Contact authorized dealers of this product.
If they can’t supply original replacement
part(s), call FMI PRODUCTS, LLC at
1-866-328-4537.
When calling, have ready:
your name
your address
model and serial numbers of your heater
how heater was malfunctioning
purchase date
Usually, we will ask you to return the part to
the factory.
SERVICE HINTS
When Gas Pressure Is Too Low
pilot will not stay lit
burners will have delayed ignition
replace will not produce specied heat
propane/LP gas supply might be low (pro-
pane/LP units only)
You may feel your gas pressure is too low. If
so, contact your local gas supplier.
TECHNICAL SERVICE
You may have further questions about
installation, operation, or troubleshooting.
If so, contact FMI PRODUCTS, LLC at
1-866-328-4537. When calling please have
your model and serial numbers of your
heater ready.
You can also visit FMI PRODUCTS, LLC’s
web site at www.fmiproducts.com.
(V)T32N-A Series, (V)T32N-A-HA Series,
CGDV32NR and CTDV32NR-HA
Rating: 12,000/18,000 Btu/Hr
Type Gas: Natural Gas Only
Ignition: Piezo
Manifold Pressure:
Models (V)T32N-A Series and CGDV32NR
3.5" W.C.
Models (V)T32N-A-HA series and
CTDV32NR-HA 3.8" W.C.
Minimum Inlet Gas Pressure (W.C.): 5.5"
Dimensions (H x W x D) (Firebox only. Does
not include nailing anges or standoffs):
32
1
/
4
" x 34
1
/
2
" x 16
5
/
8
"
Fireplace Weight*: 80 lb
Shipping Weight*: 83 lb
*For refractory lined models add 45 lb
(V)T32P-A Series and CGDV32PR
Rating: 11,000/17,000 Btu/Hr
Type Gas: Propane/LP Gas Only
Ignition: Piezo
Manifold Pressure: 10" W.C.
Minimum Inlet Gas Pressure (W.C.): 11"
Dimensions (H x W x D) (Firebox only. Does
not include nailing anges or standoffs):
32
1
/
4
" x 34
1
/
2
" x 16
5
/
8
"
Fireplace Weight*: 80 lb
Shipping Weight*: 83 lb
*For refractory lined models add 45 lb