FMI (V)T32N-A Indoor Fireplace User Manual


 
www.fmiproducts.com
116646-01J 27
LIGHTING
INSTRUCTIONS
1. STOP! Read the safety information on
page 26.
2. Open lower louver panel.
3. Turn off all electric power to replace.
4. Push in gas control knob slightly and turn
clockwise
to OFF.
5. Wait ve (5) minutes to clear out any gas.
Then smell for gas, including near the
oor. If you smell gas, STOP! Follow “B”
in the safety information on page 26. If
you don't smell gas, go to the next step.
6. The pilot is located by the main burner and
should not require accessing for lighting.
7. Turn gas control knob counterclockwise
to PILOT (see Figure 51).
8. Push in gas control knob all the way and
hold. Immediately light the pilot by repeat-
edly pressing the piezo spark ignitor until
a ame appears. Continue to hold for
about 1 minute after pilot is lit. Release
gas control knob and it will pop back. Pilot
should remain lit. If it goes out, repeat
steps 4 through 8.
If gas control knob does not pop up when
released, stop and immediately call your
service technician or gas supplier.
If pilot will not stay lit after several tries,
turn gas control knob to OFF and call
your service technician or gas supplier.
9. Turn on all electric power to replace.
10. Turn gas control knob counterclockwise
to ON.
11. This valve is equipped with a HI/LO fea-
ture. Set replace input as desired.
12. To leave pilot lit and shut off burners only,
turn control knob clockwise
to the
PILOT position or set selector switch in
the OFF position.
13. Close lower louver panel.
O
F
F
P
I
L
O
T
L
O
I
H
O
N
Piezo Ignitor
Gas Control
Knob
Variable Control Knob
Figure 51 - Control Valve
OPERATION
Continued
TO TURN OFF GAS
TO APPLIANCE
1. Open lower louver panel.
2. Set selector switch in the OFF position to
prevent draining battery.
3. Turn off all electrical power to appliance
if service is to be performed.
4. Push in gas control knob slightly and turn
clockwise
to OFF.
5. Close lower louver panel.
MANUAL LIGHTING
PROCEDURE
1. Remove glass door (see Removing/Re-
placing Glass Door, page 24).
2. Follow steps 1 through 8 under Lighting
Instructions.
3. Press gas control knob and light pilot with
match.
4. Keep gas control knob pressed in for
30 seconds after lighting pilot. After 30
seconds, release gas control knob. Fol-
low steps 10 through 13 under Lighting
Instructions.
5. Replace glass door (see Removing/Re-
placing Glass Door, page 23).
OPTIONAL HAND-HELD
REMOTE OPERATION
Note: All remote control accessories must
be purchased separately (see Accessories,
page 37). Follow instructions included with
the remote control.
NOTICE: You must light the pilot
before using the hand-held re-
mote control unit. See Lighting
Instructions.
After lighting, let pilot ame burn for about
one minute. Turn control knob to ON posi-
tion. Adjust ame adjustment knob anywhere
between HI and LO. Slide selector switch to
the REMOTE position (see Figure 52, page
28). Note: The burner may light if hand-held
remote was on when selector switch was last
turned off. You can now turn the burner on and
off with the hand-held remote control unit.
IMPORTANT: Do not leave selector switch in
the REMOTE or ON position when the pilot
is not lit. This will drain the battery.