SERVICE HINTS

pilot will not stay lit
burner will have delayed ignition
replace will not produce specied heat
propane/LP gas supply may be low (pro-
pane/LP only)
You may feel your gas pressure is too low. If
so, contact your local propane/LP or natural
gas supplier.
TECHNICAL SERVICE
You may have further questions about
installation, operation, or troubleshooting.
If so, contact FMI PRODUCTS, LLC at
1-866-328-4537. When calling please have
your model and serial numbers of your
heater ready.
You can also visit our web site at
.
REPLACEMENT PARTS
If this product is missing a part or has a broken
component, please do not return it to the store.
Call FMI PRODUCTS, LLC at 1-866-328-4537
to answer questions and replace parts under
warranty.
Note: Use only original replacement parts.
This will protect your warranty coverage for
parts replaced under warranty.
When calling, have ready:
your name
your address
model and serial numbers of your heater
how heater was malfunctioning
purchase date

Rating (Variable): 14,000/26,000 Btu/Hr
Gas Type: Propane/LP Gas Only
Ignition: Piezo
Pressure Regulator Setting: 8" W.C.
Inlet Gas Pressure (in. of water):
Maximum - 14" W.C., Minimum* - 11" W.C.
* For purposes of input adjustment

Dimensions (H x W x D) (including hood and screws):
Fireplace - 25
7
/8"
x 26
13
/16" x 9
3
/8", Carton - 32
5
/8" x 27
3
/16" x 11
5
/8"
Weight: Fireplace - 44.5 lbs., Shipping - 48 lbs.
SPECIFICATIONS
CGCFTNA
Rating (Variable): 14,000/26,000 Btu/Hr
Gas Type: Natural Gas Only
Ignition: Piezo
Pressure Regulator Setting: 3" W.C.
Inlet Gas Pressure (in. of water):
Maximum - 10.5" W.C., Minimum* - 5" W.C.
* For purposes of input adjustment