FMI CGCFTNA Indoor Fireplace User Manual


 
www.fmiproducts.com
124978-01B 27

 
 
 

 -

 
IMPORTANT: Operating replace where impurities in air exist may create odors. Cleaning
supplies, paint, paint remover, cigarette smoke, cements and glues, new carpet or textiles,
etc., create fumes. These fumes may mix with combustion air and create odors.

1. Fireplace burning vapors
from paint, hair spray,
glues, etc. (See IMPOR-
TANT statement above)
2. Low fuel supply (propane/
LP)
3. Gas leak.  

1. Not enough fresh air is
available
2. Low line pressure
3. ODS/pilot is partially
clogged
1. Gas leak.  

2. Control valve defective
1. Foreign matter between
control valve and burner
2. Gas leak.  

1. Not enough combustion/
ventilation air
REMEDY
1. Ventilate room. Stop us-
ing odor causing products
while replace is running
2. Rell supply tank
3. Locate and correct all leaks
(see Checking Gas Con-
nections, page 18)
1. Open window and/or door
for ventilation
2. Contact local propane/LP
or natural gas company
3. Clean ODS/pilot (see
Cleaning and Maintenance,
page 23)
1. Locate and correct all leaks
(see Checking Gas Con-
nections, page 18)
2. Replace control valve
1. Take apart gas tubing and
remove foreign matter
2. Locate and correct all leaks
(see Checking Gas Con-
nections, page 18)
1. Refer to Air for Combustion
and Ventilation require-
ments (page 6)

Fireplace produces unwant-
ed odors
Fireplace shuts off in use
(ODS operates)
Gas odor even when control
knob is in OFF position
Gas odor during combus-
tion
Moisture/condensation no-
ticed on windows
TROUBLESHOOTING
Continued