FMI CGCFTNA Indoor Fireplace User Manual


 
www.fmiproducts.com
124978-01B 11
IMPORTANT: When nishing your rebox,
combustible materials
WARNING: Do not allow any



WARNING: Do not allow
  



-


    

   -
cal outlet is included with the


-

2. If installing GA3450TA blower accessory,
do so at this time. See Installing Blower
Accessory GA3450TA, page 13.
Note: If not installing blower accessory,
you may wish to run electrical wiring to
your replace for future blower installa-
tion (see Accessories, page 29) Use only
approved three-wire electrical wiring.
Note: A qualied installer should make all
electrical connections.
3. Install gas piping to replace location. This
installation includes an approved exible
gas line (if allowed by local codes) after
the equipment shutoff valve. The exible
gas line must be the last item installed on
the gas piping.
4. If you have not assembled rebox, follow
instructions on page 4.
5. Carefully set replace in front of rough
opening with back of replace inside wall
opening.
6. Attach exible gas line to replace gas
regulator. See Connecting to Gas Supply,
page 16.
7. Bend four nailing anges on outer casing
with pliers (see Figure 10).
8. Attach replace to wall studs using nails
or wood screws through holes in nailing
ange.
9. Check all gas connections for leaks. See
Checking Gas Connections, page 18.
10. If using optional trim kit, install the trim
after nal nishing and/or painting of wall.
See instructions included with trim acces-
sory for attaching trim.
INSTALLATION
Continued
36
5
/
8
"
25
7
/
8
"
51
3
/
4
"
26
7
/
8
"
Figure 9 - Rough Opening for Installing
in Corner
26
7
/
8
"
26
7
/
8
"
3/4" Off
The Floo
r
Minimum
10
1
/
2
"
Figure 8 - Rough Opening for Installing
in Wall
Figure 10 - Attaching Fireplace to Wall
Studs
Nails or
Wood
Screws
Nailing
Flanges