Enviro 50-1033 Indoor Fireplace User Manual


 
8
Operating Instructions
For Your Safety, Read Safety Precautions And
Lighting Instructions Before Operating
Remote contRoLs (oPtionaL):
This replace can use an optional remote control or an optional cordless wall thermostat. If either of
these are to be used to control the replace for the majority of the time, leave the ON/OFF switch (on the
control panel) in the remote/thermostat position. Consult the instructions included with the remote/wall
thermostat for operation guidelines.
bLoweR sPeeD (oPtionaL):
The blower will come on only when the replace is up to temperature (approximately 20 minutes). The
speed of the fan can be changed by turning the fan control knob. To turn the blower off, turn the knob
COUNTER CLOCKWISE until it “clicks” off.
It is advisable not to operate the blower below
1
/3 speed as it puts a strain on the windings of the blower
and running the blower at lower speeds could also cause premature fan failure.
noRmaL sounDs DuRing oPeRation:
Table 2: Normal Sounds
Component Sound & Reason
Westport Creaking when heating up or cooling down.
Burner Light pop or poof when turned off; this is more common with LP units.
Temperature Sensor Clinking when it senses to turn the blower on or off.
Pilot Flame Quiet whisper while the pilot ame in on.
Blower / Fan Air movement that increase and decreases with the speed of the blower. The
blower is pushing the heat from the replace into the room.
Gas Control Valve Dull click when turning on or off, this is the valve opening and closing.