Enviro 50-1033 Indoor Fireplace User Manual


 
Initial Installation
QUALIFIED INSTALLERS ONLY
venting into a cLass ‘a’ chimney:
This model is also certied and tested to vent into CLASS ‘A’ wood stove chimneys.
Place the freestanding direct vent appliance in the desired location.
Use a conversion kit from Simpson Duravent (931, 932,
or 933), or Security Chimney (SV4CCK1, SV4CCK2, or
SV4CCK1). Which kit is used will depending on the inner
diameter of the CLASS ‘A’ chimney that this appliance is
to be vented into.
Place a bead of high temperature silicone or mil-pac at
each connection to ensure a tight seal.
NOTE: An approved 4” (10 cm) diameter ex liner must
be used in the application.
NOTE: Use Simpson Dura Vent from the top of the
appliance until this vent reaches the CLASS ‘A’ chimney.
Install the retro adapter to the top section of GS direct
vent pipe and install the ex liner to the retro adapter.
Fully line the CLASS ‘A’ chimney with a minimum 4” (10
cm) ex liner to the top of the CLASS ‘A’ chimney.
Place a bead of high temperature silicone to the Simpson
Cap adapter and securely attach the ex liner to the
adapter.
Secure the cap adapter to the CLASS ‘A’ chimney
ensuring an airtight seal.
Install the vertical termination cap.
Light the unit and ensure proper operation.
THE USE OF ANY EXISTING CHIMNEY AS AN AIR INTAKE
IS NOT COVERED UNDER THE ANSI Z21.88-2002 CSA
2.33a-2002 TEST METHODS AND THE RESULTING ITS/
WH PRODUCT CERTIFICATION. THE CODE AUTHORITY
HAVING JURISDICTION MUST BE CONSULTED PRIOR
TO PROCEEDING WITH THIS INSTALLATION METHOD.
Simpson GS
Dura Vent Cap
Cap Adapter
Class ‘A’
Chimney
Roof Flashing
4”(10cm) Flex Liner
Inside Class ‘A’Chimney
Ceiling Rafters
GS Simpson Dura
Vent Pipe 4”x 6
5
/
8
Figure 39: Assembly of Venting into a Class ‘A’
Chimney.
26
conveRting toP venteD into ReaR venteD:
This unit has been shipped as a 30,000 Btu/hr top-vented freestanding unit. This unit can be converted
to a rear vented unit with a 36” (915 mm) snorkel for some installation applications.To convert this unit
to a rear vented model you must remove the ue pipe adapter and turn to the rear vent position. See
sections initial inStallation - inStallation of rear vented aPPliance.
1. Carefully remove the trivet and the stovetop. Place on a soft surface as not to damage the porcelain
nishes.