Desa L32, L36 L36, L42, L32, L36, L36, L42 Indoor Fireplace User Manual


 
www.desatech.com
115254-01A 17
Tee Cap Pipe
Joint Nipple
We recommend that you install a sediment trap in
supply line as shown in Figures 21 and 22, depend
-
ing on your model. Locate sediment trap where it is
within reach for cleaning. Install in piping system
between fuel supply and heater. Locate sediment
trap where trapped matter is not likely to freeze.
A sediment trap traps moisture and contaminants.
This keeps them from going into heater controls. If
sediment trap is not installed or is installed wrong,
heater may not run properly.
CAUTION: Avoid damage to
regulator. Hold gas regulator
with wrench when connecting
it to gas piping and/or fittings
(Variable Manually-Controlled
Models Only).
CAUTION: Avoid damage to
gas control. Hold gas control
with wrench when connecting
it to gas piping and/or fittings
(Remote-Ready Models Only).
Figure 22 - Attaching Flexible Gas Line
to Control Valve (Remote-Ready Models)
* Purchase the optional CSA design-certified
equipment shutoff valve from your dealer. See
Accessories, page 35.
**Minimum inlet pressure for purpose of input
adjustment
Approved
Flexible
Gas Hose (if
allowed by
local codes)
Pipe Cap Tee
Nipple Joint
3" Minimum
Sediment Trap
Propane/LP
- From External
Regulator
(11" W.C.** to 14"
W.C. Pressure)
Natural - From
Gas Meter (5"
W.C.** to 10.5"
W.C. Pressure)
Gas
Control
CSA Design-Certified
Equipment Shutoff Valve
with 1/8" NPT Tap*
CHECKING GAS CONNECTIONS
WARNING: Test all gas piping
and connections, internal and
external to unit, for leaks after
installing or servicing. Correct
all leaks at once.
WARNING: Never use an
open flame to check for a leak.
Apply a noncorrosive leak detec-
tion fluid to all joints. Bubbles
forming show a leak. Correct all
leaks at once.
CAUTION: Make sure exter-
nal regulator has been installed
between propane/LP supply and
heater. See guidelines under Con-
necting to Gas Supply, page 16.
INSTALLATION
Continued
Figure 21 - Attaching Flexible Gas Line to
Control Valve (Manually-Controlled Models)
Propane/LP
From External
Regulator
(11" W.C.**
to 14" W.C.
Pressure)
Natural
From Gas
Meter (5"
W.C.** to
10.5" W.C.
Pressure)
CSA Design-
Certified Equipment
Shutoff Valve with
1/8" NPT Tap*
Approved
Flexible
Gas Hose (if
allowed by
local codes)
3" Minimum
Sediment Trap
Gas
Regulator