INSTALLATION
Continued
HARD-WIRING FIREBOX
NOTICE: A qualified electrician
must connect electrical wiring to
duplex outlet for built-in instal
-
lation. Follow all local codes.
In absence of local codes fol
-
low The National Electric Code
ANSI/NFPA 70.
The “Handy Box” with duplex outlet is provided in
the firebox located in the lower right base area.
1. Remove screw holding duplex outlet cover to
handy box. Remove duplex outlet.
2. Route electrical cable through strain relief and
handy box (see Figure 17).
3. Connect electrical cable to duplex outlet.
Match wire colors to those on duplex outlet.
Be sure to connect the ground wire.
4. Place duplex outlet back into handy box and
secure with screws. Replace outlet cover.
Strain Relief
Duplex Box/
Handy Box
Figure 17 - Hard-Wiring Firebox
INSTALLING FIREPLACE HOOD
AND SCREEN
1. Attach hood to firebox using screws provided
(see Figure 18).
2. Insert each rod through all rings located at top
of screen.
3. Insert first rod into rear hole in left side of
firebox. Fasten rod to rear hole near center
of firebox using #10 x 3/8" Phillips screw
provided (see Figure 19).
4. Insert other rod into front hole on right side
of firebox and fasten using remaining Phillips
screw.
Figure 18 - Screw and Hood Placement
(Model May Vary From Illustration)
Figure 19 - Installing Fireplace Screen
(Model May Vary From Illustration)
Screw
Rear Hole
Top View of Rod Layout
Rod
Front
Hole
Ring
Screen
Identification