B. Clearances from the top of the firebox opening to
the ceiling should not be less than 42 inches.
C. When the firebox is installed on carpeting or
other combustible material, other than wood
flooring, the firebox should be installed on a
metal or wood panel extending the full width
and depth of the enclosure.
D. Clearances from the bottom of firebox to the
floor is 0 inches.
These fireboxes can be installed as freestanding
units against a wall with the approved, optional
cabinet mantels (see
Accessories, page 35) or as a
built-in unit. The clearances are the same for either
installation method.
CAUTION: Do not install
the firebox directly on carpet
or vinyl.
INSTALLATION
Continued
Figure 5 - Minimum Clearance for
Combustible to Wall
*Minimum 16 inches from Side Wall
*
Mantel Clearances for Built-In Installation
If placing custom mantel above built-in firebox,
you must meet the minimum allowable clearance
between mantel shelf and top of firebox opening
shown in Figure 6. These are the minimum allow
-
able mantel clearances for a safe installation. Use
larger clearances wherever possible to minimize
the heating of objects and materials placed on
the mantel.
CAUTION: Do not allow
the vent-free gas log heater
to touch or extend beyond the
fireplace screen.
Example
NOTICE: Surface temperatures
of adjacent walls and mantels be-
come hot during operation. Walls
and mantels above the firebox
may become hot to the touch.
If installed properly, these tem-
peratures meet the requirement
of the national product standard.
Follow all minimum clearances
shown in this manual.
NOTICE: If your installation does
not meet the minimum clearances
shown, you must do one of the
following:
• raise the mantel to an accept-
able height
• remove the mantel
BUILT-IN FIREBOX INSTALLATION
Built-in installation of this firebox involves install-
ing firebox into a framed-in enclosure. This makes
the front of firebox flush with wall. Optional brass
trim accessories are available (see Accessories,
page 35). The brass trim will extend past sides of
firebox approximately 1/2 inch. This will cover
the rough edges of the wall opening. If installing
a mantel above the firebox, you must follow the
clearances shown in Figure 6. Follow these instruc-
tions to install the firebox in this manner.
Figure 6 - Minimum Mantel Clearances
for Built-In Installation
Supplied Firebox
Hood Must Be
Used at All Times
Wire-mesh
Screen
Firebox
Noncombustible
Material May
Project Off this
Surface above
the Firebox Hood
Mantel Shelf
Note: Any portion of the
mantel shelf must NOT
extend beyond this profile.
12"
16"
20"
1
1
/2
"
6
3
/4
"
12"
Note: All vertical
measurements are
from top of fireplace
hood opening to
bottom of mantel shelf.
These minimum
clearances replace any
other recommended
clearances supplied with
your ANSI Z21.11.2
approved gas logs.
Wa
ll board or facing
material (above
firebox) may be of
combustible material,
including decorative
mantel ornaments or
other similar projec-
tions off of the facing
material.
Framing
Material