82
PERFORMANCE DATA — 549B, 549C
COOLING CAPACITIES
549B036 (3 Tons)
Temp (F)
Outdoor
Entering Air
(Edb)
Indoor Entering Air — Cfm/BF
900/0.12 1200/0.15 1500/0.18
Indoor Entering Air — Ewb (F)
72 67 62 72 67 62 72 67 62
75
TC 41.2 37.8 34.4 42.9 39.6 36.3 43.6 40.6 37.5
SHC 19.8 24.5 28.8 21.5 27.6 32.9 22.5 30.1 36.3
kW 2.11 2.08 2.05 2.12 2.10 2.07 2.12 2.10 2.08
85
TC 39.9 36.5 33.1 41.9 38.2 34.9 42.5 39.2 36.1
SHC 19.4 24.0 28.2 21.2 27.2 32.4 22.6 29.8 35.9
kW 2.36 2.34 2.31 2.38 2.35 2.33 2.38 2.36 2.35
95
TC 38.6 35.0 31.7 40.4
36.7 33.4 41.3 37.6 34.8
SHC 18.9 23.4 27.4 20.8
26.6 31.6 22.4 29.2 34.7
kW 2.65 2.62 2.58 2.66
2.63 2.61 2.67 2.64 2.63
105
TC 37.1 33.2 30.0 38.7 35.0 31.5 39.3 36.0 33.2
SHC 18.3 22.7 26.6 20.3 26.1 30.7 21.7 29.0 33.2
kW 2.96 2.92 2.88 2.98 2.95 2.90 2.97 2.96 2.93
115
TC 35.1 31.4 28.0 36.7 32.8 29.7 37.7 33.8 31.6
SHC 17.6 21.9 25.6 19.7 25.2 29.6 21.5 28.1 31.6
kW 3.29 3.25 3.20 3.31 3.27 3.23 3.32 3.29 3.26
125
TC 33.0 29.0 25.7 34.4 30.6 27.8 35.4 31.5 29.8
SHC 16.9 21.0 24.5 19.0 24.3 27.8 20.9 27.1 29.7
kW 3.65 3.59 3.53 3.68 3.62 3.57 3.69 3.64 3.61
549B048 (4 Tons)
Temp (F)
Outdoor
Entering Air
(Edb)
Indoor Entering Air — Cfm/BF
1200/0.1 1600/0.12 2000/0.15
Indoor Entering Air — Ewb (F)
72 67 62 72 67 62 72 67 62
75
TC 51.0 48.9 43.9 52.3 50.2 46.0 53.7 51.5 48.1
SHC 24.1 33.1 40.3 26.0 37.0 44.2 27.8 40.9 48.0
kW 2.65 2.64 2.60 2.66 2.65 2.61 2.67 2.66 2.63
85
TC 48.9 47.1 41.9 50.7 48.4 44.2 52.6 49.8 46.6
SHC 22.9 32.2 40.2 25.4 36.4 43.4 27.9 40.6 46.6
kW 2.99 2.98 2.94 3.01 3.00 2.96 3.03 3.01 2.99
95
TC 47.1 45.1 39.2 49.0
46.3 42.1 50.8 47.6 44.9
SHC 22.3 31.5 39.2 24.9
35.6 42.1 27.4 39.8 44.9
kW 3.37 3.37 3.31 3.40 3.38 3.34 3.42 3.39 3.37
105
TC 44.9 42.9 37.5 46.8 44.1 40.3 48.7 45.4 43.2
SHC 21.3 30.7 37.5 24.1 34.8 40.3 26.9 39.0 43.1
kW 3.79 3.78 3.71 3.82 3.80 3.75 3.84 3.81 3.79
115
TC 42.9 40.8 35.2 44.6 41.9 38.3 46.3 43.0 41.3
SHC 20.4 30.1 35.2 23.3 34.0 38.3 26.1 37.9 41.3
kW 4.24 4.23 4.15 4.26 4.24 4.19 4.29 4.25 4.23
125
TC 40.9 38.2 32.9 42.2 39.3 36.1 43.5 40.5 39.3
SHC 19.8 29.1 32.9 22.4 33.0 36.1 25.1 36.9 39.3
kW 4.72 4.70 4.62 4.73 4.71 4.66 4.74 4.72 4.71
549B060 (5 Tons)
Temp (F)
Outdoor
Entering Air
(Edb)
Indoor Entering Air — Cfm/BF
1500/0.17 1750/0.25 2000/0.31
2500/0.42
Indoor Entering Air — Ewb (F)
72 67 62 57 72 67 62 57 72 67 62 57 72 67 62 57
75
TC 70.2 65.3 59.9 56.6 71.7 66.8 61.9 59.7 72.8 67.8 63.4 62.4 74.1 69.9 65.8 65.8
SHC 31.6 40.6 49.2 54.1 33.3 43.5 53.8 57.0 34.8 46.0 57.8 59.6 37.5 51.8 62.9 62.9
kW 3.51 3.47 3.45 3.43 3.52 3.48 3.46 3.44 3.45 3.49 3.47 3.46 3.55 3.51 3.48 3.48
85
TC 68.7 63.3 57.4 54.2 70.3 65.1 59.3 57.8 71.8 66.3 60.9 60.5 73.2 68.5 64.5 64.4
SHC 31.3 40.0 48.3 51.8 33.1 43.2 52.8 55.2 34.9 46.2 56.8 57.7 38.0 52.5 61.6 61.5
kW 3.95 3.91 3.89 3.87 3.96 3.92 3.89 3.89 3.98 3.93 3.91 3.91 4.00 3.96 3.93 3.92
95
TC 66.7 60.6 52.0 50.1 68.4 62.4 55.5 54.7 69.1
63.8 58.2 58.2 71.2 65.6 62.2 62.2
SHC 30.7 39.1 46.2 47.8 32.7 42.5 51.3 52.3 34.2
45.8 55.5 55.5 38.0 51.6 59.4 59.4
kW 4.43 4.39 4.34 4.32 4.45 4.41 4.37 4.37 4.46
4.43 4.39 4.40 4.48 4.43 4.42 4.42
105
TC 63.7 55.4 45.8 45.8 65.6 58.6 50.2 50.1 66.9 60.5 53.3 53.6 68.2 62.4 59.5 59.5
SHC 29.8 37.4 43.5 43.7 31.9 41.3 47.9 47.9 33.9 44.8 50.9 51.2 37.3 51.1 56.8 56.8
kW 4.96 4.91 4.81 4.81 4.99 4.94 4.86 4.86 5.00 4.96 4.90 4.90 5.00 4.97 4.95 4.95
115
TC 60.2 47.9 41.2 41.2 62.0 50.9 45.2 45.2 63.3 52.8 48.2 48.2 65.1 56.2 54.2 54.1
SHC 28.8 34.8 39.3 39.3 30.9 38.8 43.1 43.2 32.9 42.4 46.1 46.0 36.8 49.2 51.8 51.7
kW 5.55 5.43 5.33 5.33 5.57 5.46 5.40 5.40 5.58 5.49 5.44 5.44 5.59 5.53 5.50 5.50
Standard Ratings
LEGEND
NOTES:
1. Direct interpolation is permissible. Do not
extrapolate.
2. The following formulas may be used:
Where: h
ewb
= Enthalpy of air entering evapo-
rator coil
3. The SHC is based on 80 F edb temperature of
air entering evaporator coil.
Below 80 F edb, subtract (corr factor x cfm)
from SHC.
Above 80 F edb, add (corr factor x cfm) to
SHC.
Correction Factor = 1.10 x (1 – BF) x
(edb – 80).
Interpolation is permissible.
Correction Factor = 1.10 x (1 – BF) x
(edb – 80).
BF — Bypass Factor
Edb — Entering Dry-Bulb
Ewb — Entering Wet-Bulb
kW — Compressor Motor Power Input
SHC — Sensible Heat Capacity (1000 Btuh) Gross
TC — Total Capacity (1000 Btuh) Gross
t
ldb
=t
edb
–
sensible capacity
(Btuh)
1.10 x cfm
t
lwb
= Wet-bulb temperature
corresponding to enthalpy of air
leaving evaporator coil (h
lwb
)
h
lwb
=h
ewb
–
total capacity
(Btuh)
4.5 x cfm
BYPASS
FACTOR
(BF)
ENTERING AIR
DRY-BULB TEMP (F)
79 78 77 76 75
under
75
81 82 83 84 85
over
85
Correction Factor
.05 1.04 2.07 3.11 4.14 5.18
Use
formula
shown
below.
.10 .98 1.96 2.94 3.92 4.90
.20 .87 1.74 2.62 3.49 4.36
.30 .76 1.53 2.29 3.05 3.82
549B, 549C