Bryant 310AAV Furnace User Manual


 
14
Table 5—Air Delivery -- CFM (with Filter)*
FURNACE
SIZE
RETURN---AIR
INLET
SPEED
EXTERNAL STATIC PRESSURE (In. W.C.)
0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1.0
045---08/
024045
Bottom or
Side(s)
High
Med --- Hig h
Med --- L ow
1035
865
760
995
830
720
945
790
680
895
745
635
835
690
580
770
625
520
675
545
445
565
440
345
390
250
220
195
195
195
045---12/
036045
Bottom or
Side(s)
High
Med --- Hig h
Med --- L ow
1440
1360
1250
1375
1300
1210
1305
1240
1160
1240
1175
1100
1160
1115
1040
1070
1040
965
975
950
885
870
850
790
730
725
670
560
575
520
070---08/
024070
Bottom or
Side(s)
High
Med --- Hig h
Med --- L ow
1030
835
725
1005
815
700
965
790
675
925
755
635
870
710
595
810
660
545
740
590
460
645
480
350
465
325
250
280
205
--- ---
070---12/
036070
Bottom or
Side(s)
High
Med --- Hig h
Med --- L ow
1425
1320
1200
1375
1280
1175
1320
1240
1145
1265
1205
1105
1200
1140
1050
1125
1075
990
1035
995
920
940
905
840
830
790
725
655
620
555
070---16/
048070
Bottom or
Side(s)
High
Med --- Hig h
Med --- L ow
1755
1550
1355
1700
1520
1340
1635
1475
1310
1570
1430
1280
1505
1375
1240
1435
1310
1190
1350
1240
1125
1260
1155
1060
1160
1070
975
1055
970
890
090---14/
042090
Bottom or
Side(s)
High
Med --- Hig h
Med --- L ow
1605
1470
1310
1570
1445
1295
1535
1410
1265
1465
1380
1230
1385
1300
1195
1285
1220
1120
1175
1115
1025
1055
990
915
895
830
710
645
600
565
090---16/
048090
Bottom or
Side(s)
High
Med --- Hig h
Med --- L ow
1940
1740
1505
1880
1700
1505
1805
1650
1480
1720
1590
1440
1635
1525
1375
1540
1440
1300
1425
1335
1190
1290
1195
1045
1090
1010
890
830
820
740
090---20/
060090
Bottom Only
High
Med --- Hig h
Med --- L ow
2405
2170
1920
2310
2110
1875
2220
2040
1835
2130
1970
1780
2025
1895
1715
1920
1785
1630
1790
1675
1535
1660
1565
1420
1530
1420
1275
1350
1260
1135
Both Sides or 1
Side & Bottom
High
Med --- Hig h
Med --- L ow
2530
2230
1895
2450
2170
1890
2365
2110
1845
2270
2050
1815
2165
1985
1755
2065
1890
1685
1940
1780
1600
1805
1660
1480
1670
1525
1350
1505
1360
1180
1Side Only
High
Med --- Hig h
Med --- L ow
2475
2105
1850
2395
2145
1860
2300
2070
1810
2200
2010
1770
2090
1940
1715
1985
1845
1650
1865
1735
1555
1730
1620
1445
1585
1475
1310
1425
1325
1150
110---12/
036110
Bottom or
Side(s)
High
Med --- Hig h
Med --- L ow
1600
1475
1315
1550
1435
1295
1490
1395
1265
1425
1335
1220
1355
1285
1155
1260
1185
1080
1135
1070
985
990
890
810
785
725
675
530
450
440
110---16/
048110
Bottom or
Side(s)
High
Med --- Hig h
Med --- L ow
1980
1745
1530
1915
1710
1515
1835
1650
1470
1750
1560
1400
1655
1450
1310
1495
1340
1215
1365
1205
1095
1185
1090
990
965
865
830
700
605
670
110---22/
066110
Bottom Only
High
Med --- Hig h
Med --- L ow
2485
2135
1855
2415
2100
1840
2340
2060
1815
2255
2000
1775
2160
1930
1725
2080
1860
1675
1950
1765
1600
1840
1670
1510
1720
1555
1405
1565
1425
1290
Bottom Sides
or 1 Side & Bot-
tom
High
Med --- Hig h
Med --- L ow
--- ---
2140
1855
--- ---
2100
1840
2355
2050
1815
2285
1990
1775
2190
1935
1725
2090
1865
1675
1965
1760
1600
1850
1670
1510
1705
1545
1405
1535
1410
1290
1Side Only
High
Med --- Hig h
Med --- L ow
2495
2030
--- ---
2440
2025
1735
2370
2000
1725
2290
1950
1695
2205
1905
1650
2120
1850
1595
2015
1750
1535
1910
1660
1455
1775
1555
1335
1625
1425
1230
* A filter is required for each return---air inlet. A irflow performance i ncluded 3 /4---in. (19 mm) washable filter media s uch as contained in factory--- authorized ac-
cessory filter rack. To determine airflow performance without this filter, assume an additional 0.1 In. W.C. available external static pressure.
------ Indicates unstable operating conditions.
310AAV