Bosch Appliances LTC 8800 Home Security System User Manual


 
LTC 8600 | LTC 8800 Series en | 23
F.01U.127.393 | 2.0 | 2009.03 Instruction Manual Bosch Security Systems, Inc.
7.24 LTC 8506/00 PC-to-Console Port RS-232 Cable
The LTC 8506/00 is an RS-232 grade cable with 9-pin D-connectors on each end that
is used to connect an Allegiant's system's console port to a standard PC COM port.
This cable is included in the Allegiant LTC 8059 MCS and the
LTC 8850 Allegiant GUI packages. Length is approximately 3 m (10 ft).
7.25 LTC 8508/01 Ribbon-to-BNC Interface Cable
The LTC 8508/01 is a 1 m (3 ft) video interface cable with a 34-pin ribbon cable on
one end and 16 male BNC connectors on the other end. This cable can be used to
loop up to 16-channels of video signals from digital video recorders such as the
Divar, Dibos, and DesaXL, or other BNC equipped devices to the ribbon cable con-
nectors located on the rear panels of the LTC 8600 and LTC 8800 Series bays.
7.26 Logging Printer
An optional RS-232 serial printer may be connected to these systems to provide a
permanent record of significant system status changes. Time and date is printed for
system events such as alarms, start-up after power failure, sequence loading, opera-
tor log-on/log-off to keyboards, and download of information from the optional
MCS. The printer may also be used to obtain hard copies of all system tables and
sequences.
NOTE The printer port does not provide a standardized pin-out connection. If desired, a
cable can be made up at installation, by following the cable pin-out information pro-
vided at the end of this manual.