Bosch Appliances D1260 Home Security System User Manual


 
D1260/D1260B | Owner's Manual | Part IV: Multi-Area Use - Turn On the Entire System Without Delays
72 Bosch Security Systems | 9/04 | 50410D
1. Enter your passcode and press ENTER.
2. The command center will display the following:
Command center scope and/or your authority
level limit the actual number of areas you may
turn on. For example, if you have authority to arm
all 8 areas but the scope of the command center
you’re using is limited to areas 1, 2, and 5, then
you will only be able to turn on areas 1, 2, and 5.
3. If a point is faulted (door or window open for
example), see Turning On the System (Arming) With
Doors or Windows Open for further information.
Faulted Points in Other Areas
If there is a faulted point in an area you select (other
than the one you are in),
Check Area 1
(1 is used as
an example here) appears for 3 seconds and then the
display returns to the area disarmed idle text.
If there is a faulted point in more than one area and the
system is being armed, the display will prompt
Check
Area 1 3
meaning there are faulted points in Areas 1
and 3.
Try one of the following:
Clear faulted points (close doors and/or windows)
and return to step 1.
Bypass faulted points (if your system and/or
authority allows) and return to step 1.
Force arm (if your system and/or authority allows).
See Turning On the System (Arming) With Doors or
Windows Open for more information.
Turn On the Entire System Without Delays
You can use this Command Menu function to turn on
the entire system, both perimeter and interior, without
delays. You may use this function in all of the areas or
some of the areas where your passcode has authority. If
there are areas already turned on, this function turns on
all areas that are off without changing the status of the
areas that are already on.
Turning on All or Selected Areas
Areas covered in the scope of the command center can
be armed individually by accessing the Master Arm
function through the menu.
1. Press the
Menu>
key to enter the Command
Menu.
2. Press the
Next>
soft key repeatedly until you
reach the
MASTER ARM INST ?>
prompt then
press the adjacent soft key.
3. You will prompted for your passcode. It will
appear on the display as asterisks (*).
4. The display changes and shows
MASTER ARM
ALL ?
with the following options:
<Previous
soft key – will scroll to the last area
that can be armed (based on passcode and
authority level)
Next>
soft key – will scroll to the first area
that can be armed (based on passcode and
authority level)
Arm>
soft key – will arm all areas (based on
passcode and authority level)
<Exit
soft key – will return the display to idle
text