Bosch Appliances D1260 Home Security System User Manual


 
D1260/D1260B | Owner's Manual | Part II: System Commands - Silence the Trouble Sounder & Clear Trouble Display
(COMMAND + 4)
24 Bosch Security Systems | 9/04 | 50410D
Silence the Trouble Sounder & Clear
Trouble Display (COMMAND + 4)
Description
Use COMMAND 4 to silence the trouble sounder
during system events. This command also clears system
messages from the display. If an alarm has occurred
and was silenced, the *
ALARM SILENCED*
display
will continue to scroll to remind you that cleared
events can be seen with the View Memory function
(refer to VIEW MEMORY ? (COMMAND + 4 + 0) on
page 24).
Using COMMAND 4:
1. The display shows disarmed idle text.
Press the COMMAND key. The display shows
*System Command*
.
2. Press the 4 key.
3. The Keypad sounder is silenced.
VIEW MEMORY ? (COMMAND + 4 + 0)
View Event Memory
Description
Your system stores events that occurred since the last
time memory was cleared. Use COMMAND 40 to
view Event Memory.
Event Memory allows you or a service technician to
review events after they are cleared from the keypad’s
display. *
ALARM SILENCED*
will continue to scroll
to remind you that events are stored in Event Memory.
Each time you turn on the system on, the Event
Memory is erased and the
ALARM SILENCED
message is cleared.
Using View Memory:
1. The display shows disarmed idle text.
2. Press the COMMAND key. The display shows
*System Command*
.
3. Press the 4 key and then the 0 key.
If you prefer, you may use the Command
Menu in place of steps 2 and 3 to initiate
this function.
Press the MENU> soft key to enter the
Command Menu.
Press NEXT> soft key repeatedly.
When you reach the VIEW MEMORY ?>
prompt, press its adjacent soft key.
Press ENTER.