Bacharach H25-IR Carbon Monoxide Alarm User Manual


 
H25-IR Appendix A
Instruction 3015-4342 53
APPENDIX A – Factory Defaults
Table A-1 lists the factory default parameters that are determined by the instrument’s part number
(as marked on the rear panel), while Table A-2 lists the default parameters that are user definable.
Table A-1. Default Parameters Defined by Part Number
Part No. Gas Type Leak Units Range PCHK Mode Leak Source
3015-4348 R134a* Oz/yr Small Auto Internal
3015-4434 R600a g/yr Small At CAL Internal
3015-4448 R134a* g/yr Small At CAL Internal
3015-4455 R600a g/yr Small At CAL External
3015-4464 R600a Oz/yr Small Auto Internal
3015-4465 R600a Oz/yr Small Auto External
3015-4466 R227 Oz/yr Small Auto Internal
3015-4472 CO
2
Oz/yr Small Auto External
3015-4473 CO
2
Oz/yr Small Auto Internal
3015-4475 R134a* g/yr Small At CAL External
3015-4477 SF
6
Oz/yr Small Auto Internal
3015-4479 SF
6
Oz/yr Small Auto External
3015-4482 CO
2
g/yr Small At CAL External
3015-4483 CO
2
g/yr Small At CAL Internal
3015-4485 R134a* Oz/yr Small Auto External
3015-4487 SF
6
g/yr Small At CAL Internal
3015-4489 SF
6
g/yr Small At CAL External
3015-4496 R227 Oz/yr Small Auto External
3015-4578 R134a* g/yr Small At CAL Internal
3015-4588 R600a g/yr Small At CAL Internal
3015-4589 SF
6
g/yr Small At CAL Internal
3015-4594 CO
2
g/yr Small At CAL Internal
3015-4659 R134a* g/yr Small At CAL External
3015-4660 R600a g/yr Small At CAL External
3015-4661 SF
6
g/yr Small At CAL External
3015-4662 CO
2
g/yr Small At CAL External
* This instrument is capable of detecting CFC, HCFC, HFC and Halogen gases
other than R134a. Refer to Section
7 Specifications for a complete list of gases.
Table A-2. Default Parameters Defined by User
Parameter Default Setting
Relays .............................. NOT USED
Loop ................................. 0.016 ppm
Setup Name .................... SETUP NO. 1
SETUP NO. 2
SETUP NO. 3
SETUP NO. 4
Feedback Mode ............... CONTINUOUS
Setpoint ........................... 00.0000
Log Limit......................... 999.00
All of the above parameters can be reset to their default settings as described in
Section
2.4.9 Reset Defaults.