A.O. Smith SGE-40/60 Water Heater User Manual


 
Instruction manual SGE 47
is
4 Conversion to a
different gas category
4.1 Introduction
Caution
The conversion may only by carried out by a competent person.
If the appliance has to operate on a different family of gases (liquid petroleum
gas or natural gas) or gas category other than that for which the appliance has
been configured at the factory, then the appliance will have be adapted using
a special conversion kit. You can order the conversion kit you need from the
supplier of your appliance. The conversion kit contains all the parts needed to
do the conversion. A description of how to do the conversion is also delivered
with the kit.
The following conversions are possible:
1. Conversion from natural gas to LPG.
2. Conversion from LPG to natural gas.
3. Conversion from natural gas to natural gas or LPG to LPG, if applicable.
Caution
After the conversion, you must check that the appliance is gastight and
check the supply pressure, gas control valve pressure, the CO
2
value and the
switching pressure.