A.O. Smith SGE-40/60 Water Heater User Manual


 
Instruction manual SGE 35
is
3.11.2 Preparation
Caution
The water heater is phase-sensitive. It is absolutely essential to connect
the mains live (L) to the live of the water heater, and the mains neutral (N) to the
neutral of the water heater.
Caution
There must be no potential difference between neutral (N) and earth ( ).
If this is the case, then an isolating transformer (3.11.4 "
Isolating transformer")
must be used in the supply circuit.
For more information or to order this isolating transformer, please contact
A.O.Smith Water Products Company.
The figure shows a view of the terminal block, and the table explains the
relevant connections.
Connector block
In preparation, you must first remove the two covers, and the cover of the
electrical section.
1. Undo the screws of the covers.
2. Carefully remove the covers from the water heater.
The electrical section is now visible.
3. Loosen the 2 screws (A) and remove the cover (B) from the electrical
section.
The connector block (C) is now visible.
Note
Consult the table for the connections and consult the electrical diagram for
the electrical component connections.
Legend
A. screws
B. cover
C. terminal block