A.O. Smith SGE-40/60 Water Heater User Manual


 
Instruction manual SGE 9
gis
1 Introduction
1.1 About the water
heater
This manual describes how to install, service and use the SGE water heater.
The SGE water heater is a condensing boiler with a fan in the air intake. The
water is heated partly by means of an external heat exchanger that can be
connected to e.g. a solar energy source.
The SGE can be installed as either an open or room-sealed water heater. A
concentric chimney connector is fitted standard to the water heater, but a
parallel system can also be connected.
The possible installation types are B23, C13, C33, C43, C53 and C63.
The information in this manual applies to the: SGE 40 and SGE 60.
The water heater has been manufactured and equipped in accordance with the
European standard for gas-fired storage water heaters for the production of
domestic hot water (EN 89). The water heaters are therefore compliant with the
European Directive for Gas water heaters, and and are entitled to bear the CE
mark.
Warning
Read this manual carefully before starting the water heater. Failure to read
the manual and to follow the printed instructions may lead to personal injury and
damage to the water heater.
1.2 What to do if you
smell gas
Warning
If you smell gas:
No naked flames! No smoking!
Avoid causing sparks! Do not use any electrical equipment or switch, i.e. no
telephones, plugs or bells!
Open windows and doors!
Shut off the mains gas supply valve!
Warn occupants and leave the building!
After leaving the building, alert the gas distribution company or your installation
engineer.
1.3 Regulations
Gas Safety (installations and Use) Regulations 1998 (as amended). It is law
that all gas appliances are installed by competent persons, in accordance with
the above regulations. Failure to install appliances correctly could lead to
prosecution. It is in your own interest and that of safety, to ensure that this law
is complied with.
The installation of the water heater MUST be in accordance with the relevant
requirements of the Gas Safety Regulations, Building Regulations, IEE
Regulations and the Water Supply (water fittings) Regulations.
The installation should also be in accordance with any relevant requirements of
the HSE, local gas region and local authority and the relevant recommendations
of the following documents:
0063