Alliance Laundry Systems F232122R3 Water System User Manual


 
Installation
9
F232122
Mechanical Installation
Mounting Bolt Installation for Cabinet
Freestanding Models (UFPV) with
Water Saving System
Refer to the Installation/Maintenance manual
(P/N F232059) for mounting bolt installation
information for UFPV models.
Mounting Bolt Installation for Pocket
Hardmount Models (UWPV) with Water
Saving System
NOTE: The WSS frame must be permanently
attached to the floor.
All UWPV machines use 5/16-18 x 6" bolts for
mounting the tank frame. Use the mounting bolt
layouts in Figure 2.
The threaded end of the bolts should extend 2 inches
above the surface of the floor.
Refer to Figure 1 for a typical installation of individual
mounting bolts for the water saving frame.
Figure 1
Q028I
1 5/16" (8 mm)
2 6" (52 mm)
3 Frame
2
1
3