Chapter 20 Software Watchdog Timer
8.Caution
8. Caution
Although the watchdog interval time corresponds to the one twice as long as the watchdog 1-bit counter, the
watchdog timer clear operation only clears the 1-bit counter used for detecting the watchdog. As a result, the
time margin to clear the watchdog timer is different from the interval time.
Watchdog interval time selection
The watchdog timer is started once data is written in the watchdog timer control register.
The watchdog timer control register is also the reset cause register and the status (INIT, HSTB, WDOG,
ERST, SRST and LINIT) is set to “0” when it is read.
The watchdog reset holds the oscillation stability wait time.
(Refer to “Chapter 18 Timebase Counter (Page No.249)”.)
The watchdog reset from the main RUN or the sub-RUN where the main clock oscillation is in process
cannot have the oscillation stability wait time because the main clock is oscillating.
Refer to “Chapter 19 Timebase Timer (Page No.263)” for the method of clearing the timebase counter that is the
count source for the watchdog timer.
Clearing the timebase counter causes the watchdog reset timing to be postponed once.
WT1-WT0
Time margin to clear the watchdog timer Interval time during which the watchdog
reset is generated
00
Φ × 2
20
(Initial value) Φ × 2
20
to Φ × 2
21
01
Φ × 2
22
Φ × 2
22
to Φ × 2
23
10
Φ × 2
24
Φ × 2
24
to Φ × 2
25
11
Φ × 2
26
Φ × 2
26
to Φ × 2
27