DRAIN PIPING WORK
Piping and Drain Hose Installation
In case of right-side exit
Cut out the knockout portion by the slits with a knife
or pair of wire cutters as necessary.
Slit
(Body right)
Slit
(Body right)
465mm
365mm
Liquid side
Gas side
Outward form
of indoor unit
(To the front of the flare)
R 30mm
43mm
Use the handle of a screwdriver, etc.
80˚
In case of downward pipe exit
Cut out the knockout portion by the slits with a knife
or pair of wire cutters as necessary.
Piping via left-hand connection
Bend the connecting pipe so that it is laid within 43mm above the wall surface. If the connecting pipe is laid
exceeding 43mm above the wall surface, the indoor unit could be unstable when set on the wall. When bending the
connecting pipes, always use a suitable bending tool to avoid damaging the pipes.
Bend the connection pipe within a radius of 30mm.
To connect the pipe after installation of unit (figure)
NOTE :
If the pipe is bent incorrectly, the indoor unit could be unstable on the wall.
After passing the connecting pipe through the pipe hole, connect the connecting pipe to the auxiliary pipes and
insulate as necessary.