F. LIMIT POSITION AND LOCATION:
WARNING: The predetermined limit locations on all of the Thermo Pride oil fired furnaces have been
tested and approved by Thermo Products, LLC. Any attempt to relocate these safety controls or replace
these safety controls with a control that is not approved, or is incompatible, may result in personal injury,
substantial property damage or death.
G. BURNER INSTALLATION:
NOTICE: This furnace comes with a Riello BF3 burner preinstalled from the factory. If there is a need to
remove the burner prior to installation or during service, the following explains how the burner is inserted
and mounted.
The oil burner is mounted on three stud mounting bolts on the mounting plate covering the opening in the
front of the heat exchanger. This unit is designed with a pre-positioned chamber. There is no insertion
adjustment necessary. The unit requires only the mounting of the burner. Insertion is pre-determined.
The top panel is removable by taking out the four screws for easy access to the burner and the piping.
Replace this panel prior to operating the furnace.
Fig-7
H. BURNER SPECIFICATIONS AND APPLICATIONS:
The BF3 Riello flame retention oil burner is the only oil burner that can be used on the OHC.
FURNACE MODEL
THERMO
PRIDE’S
BURNER
SPEC NO.
AMULETTE
RIELLO
BURNER
MODEL &
TUBE
LENGTH
MAXIMUM
NOZZLE
SIZE**
SHIPPED
NOZZLE SIZE
OIL
PUMP
PRESSURE
(PSIG)
OHCFA072DV4R C8511373 380789 BF3-4.5”
0.50X60° H 0.50X60° H
145
Table 3: Riello burner specifications