27
Temco DV1000/1200/1400 Series
76657
FP387
SIT Valve and pilot
H
I
L
O
O
F
F
O
N
O
F
F
P
I
L
O
T
O
F
F
E
A
P
I
L
O
T
THTP
TP
TH
Pilot Screw
Wall Switch
(not supplied)
Thermopile
Pilot
Ignitor
To Piezo
Thermocouple
Manifold Pressure
Supply Pressure
IN
OUT
FP387
Fig. 37 Pilot and valve wiring.
Recommended Maximum Lead Length
(Double Wire)
When Using Wall Switch or Thermostat
Wire Size Max. Length
14 ga. 50’ (15.2 m)
16 ga. 32’ (9.8 m)
18 ga. 20’ (6 m)
20 ga. 15’ (4.6 m)
22 ga. 10’ (3 m)
NOTE: All Models are supplied with 15’ (4.6 m) of
double wire for use with a wall switch.
CAUTION: Do not wire 120V power to mil-
livolt switches or thermostats.
Managing Heat Output
The heat output from the appliance may be controlled
by adjusting the main gas valve. Reference lighting
instructions on Page 28 and chart on Page 34 showing
inputs at all the settings.
The main gas valve may be adjusted anywhere be-
tween high and low to give the desired combination of
flame aesthetics and heat output.
HI
LO
T155
PS24
hi/lo knob
11/10/03 djt
Turn knob clockwise
to increase flame
Turn knob
counterclockwise
to decrease flame
Fig. 38 Flame adjustment knob.
Fan Operation
The fan operates automatically - turn the knob on the
speed control to adjust to the desired speed. The fan
will turn on as the fireplace comes up to operating tem-
perature. After the unit has been turned off and the unit
cooled to below a useful heat output range the fan will
shut off automatically.
Flame Characteristics
It is important to periodically perform a visual check of
the pilot and burner flames. Compare them to Figure
39.
If the flame patterns appear abnormal, contact a quali-
fied service provider for service and adjustment.
Pilot Burner Adjustment
1. Adjust pilot screw to provide proper sized flame.
2. Leak test.
F584-703
Honeywell
& PSE
pilot flames
3/8” - 1/2”
(10 - 13 mm)
F584-703
Fig. 39 Correct flame appearance.